LightJet 500XL Maintenance Guide ×

Error 06 – Micropositioner Location Unknown

Possible

Micropositioner has lost servo.

Cause:

 

Recovery

Select Media/Cut and Unload. If problem persists, contact Océ.

Method:

 

Error 07 – Media Guide Stuck at Home

 

 

Possible

A) Media guides are stuck in their parked position.

Causes:

B) Mechanical component failure.

 

 

Recovery

A) Select Media/Cut and Unload. Inspect media guides. Clear physical

obstruction if present.

Methods:

B) Contact Océ.

 

 

 

Error 10 – Outfeed Timeout Fault

 

 

Possible

The bottom-of-drum sensor did not sense any media within 30 seconds.

Cause:

 

Recovery

Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media.

Method:

If error persists, contact Océ.

 

 

Communication Failures

Problems that prevent proper communication between the LightJet® 500XL and the host computer can cause total loss of communication, prevent certain functions, or corrupt the data used to generate the image. The LightJet® 500XL cannot detect:

§Whether the host computer is unable to generate the proper commands.

§Some cases of data corruption.1

§When a SCSI cable is bad or disconnected.

§When the wrong SCSI ID has been selected.2

Notes:

1The LightJet 500XL can detect some, but not all, types of data corruption.

2The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).

3-4

see copyright, disclosure, use and duplication information on pg ii

48058-A

Page 20
Image 20
Oce North America 500XL Communication Failures, Error 06 Micropositioner Location Unknown, Error 10 Outfeed Timeout Fault