LightJet 500XL Maintenance Guide ×
see copyright, disclosure, use and duplication information on pg ii 48058-A
3-4

Error 06 Micropositioner Location Unknown

Possible
Cause: Micropositioner has lost servo.
Recovery
Method: Select Media/Cut and Unload. If problem persists, contact Océ.

Error 07 Media Guide Stuck at Home

Possible
Causes:
A) Media guides are stuck in their parked position.
B) Mechanical component failure.
Recovery
Methods:
A) Select Media/Cut and Unload. Inspect media guides. Clear physical
obstruction if present.
B) Contact Océ.

Error 10 Outfeed Timeout Fault

Possible
Cause: The bottom-of-drum sensor did not sense any media within 30 seconds.
Recovery
Method:
Select Set Up/Motor Control/All Motors Reverse. Retract 150 inches of media.
If error persists, contact Océ.
Communication Failures
Problems that prevent proper communication between the LightJet® 500XL and the host
computer can cause total loss of communication, prevent certain functions, or corrupt the data
used to generate the image. The LightJet® 500XL cannot detect:
§ Whether the host computer is unable to generate the proper commands.
§ Some cases of data corruption.1
§ When a SCSI cable is bad or disconnected.
§ When the wrong SCSI ID has been selected.2
Notes:
1 The LightJet 500XL can detect some, but not all, types of data corruption.
2 The LightJet 500XL is shipped from the factory with the SCSI ID set to 6 (binary 110).