Troubleshooting
OPERATION GUIDE 4-9
Storage Error Codes
Microdrive Errors
CompactFlash Card/USB memory Errors
Code Meaning
01 Microdrive format error. If this error recurs even if the power has been
turned off and then on, reformat the Microdrive.
02 The disk system is not installed. Recheck the requirements for using the
system and the devices.
04 There is no available Microdrive space. Delete unnecessary files, etc.,
in order to free up space.
05 The specified file does not exist in the Microdrive.
06 There is no memory available to the Microdrive system. Increase the
available memory.
10 Formatting is not possible because host data is being spooled on the
Microdrive. Wait until the Microdrive is ready, and then format.
85 VMB: Alias error. The alias setting was lost, or the virtual tray
corresponding to the alias does not exist. Set the alias again.
97 The number of permanent code jobs that can be stored reached the limit
value, and no more can be saved. Either delete some unnecessary
jobs, etc., or increase the limit.
98 An unreadable page was found in a job (The job is damaged.).
99 A print job for the specified ID does not exist in the Microdrive.
Code Meaning
01 The printer does not support the CompactFlash card inserted.
02 The CompactFlash card is not installed.
04 The CompactFlash card is full and cannot hold further data. Purge
unnecessary files or use a new CompactFlash card.
05 Specified file is not on the CompactFlash card/USB flash memory.
06 Insufficient printer memory to support the CompactFlash card system.
Expand printer memory.