Omega 1002 manual D I/O Test, A/D Test

Models: 1002

1 48
Download 48 pages 45.53 Kb
Page 46
Image 46

cards.

Step 7: If a cards D/O=D/I Æ this is the physical card number, remember this number.

Step 8: Repeat the previous two steps to find the physical card number of all boards.

6.3 D I/O Test

Step 1: Power-off the PC.

Step 2: Install one OME-PCI-1002 card with a 20-pin flat cable between CON1 & CON2.

Step 3: Power-on the PC then run DEMO2.EXE.

Step 4: The DO and DI are displayed as TEST OK or TEST ERROR.

6.4 A/D Test

A/D Test for OME-PCI-1002 card Step 1: Power-off the PC.

Step 2: Install one OME-PCI-1002 card.

Step 3: Power-on PC, run DEMO6.EXE

Step 4: Apply +10V to channel 0.

Step 5: Apply +0V to channel 1.

Step 6: Apply -10V to channel 2.

Step 7: Run DEMO6.EXE.

Step 8: Check channel 0 = fff or ffe?

Step 9: Check channel 1 = 800 or 801?

Step 10: Check channel 2 = 000 or 001?

46

Page 46
Image 46
Omega 1002 manual D I/O Test, A/D Test