APPENDIX 2: TIME-NET CONFIGURATION AND CONNECTIONS.

It is advisable to make the TIME-NET connections as follows:

Transmitter

MASTER

 

 

 

Unit

 

 

 

 

 

 

 

 

1

2

3

4

Receiver

SLAVE

SLAVE

SLAVE

SLAVE

Units

 

 

 

 

Don’t connect RS-422 (JP1) line termination.

Note

Shielded twisted-pair cable, must be used for connections.

n (maximum 32 units)

SLAVE

Connect RS-422 (JP1) line termination.

MASTER

SLAVE

1

9

6

5

shield

Don’t connect the cable shield to the receiver units (slaves).

1

9

6

5

To other slaves

To other slaves

shield

COMPATIBILITY TABLE AMONG MASTER-SLAVE

master

124-C0

 

144-C0

 

 

126-C2

146-C2

slave

124-C1

144-C1

 

 

 

 

 

 

LDP-124-C

YES

NO

YES

NO

LDP-126-C

NO

YES

NO

YES

LDP-144-C

YES

NO

YES

NO

LDP-146-C

NO

YES

NO

YES