Fit the new HEPA* filter cassette into its compartment (Fig.29)
Put the bag support back into the compartment (Fig.19). Make sure that the HEPA* filter cassette is correctly positioned before closing the cover.
3 • Cleaning the HEPA* filter cassette (ref
IMPORTANT! This cleaning procedure is only for HEPA filter cassettes ref.
The HEPA* filter cassette ref.
Open the cover to your vacuum cleaner (Fig.14). Remove the bag support from the bag compartment (Fig.20), then remove the HEPA* filter cassette (Fig.30).
EN
Tap the HEPA* filter cassette above a dustbin (Fig.31).
Put the HEPA* filter cassette back in its compartment (Fig.32). Put the bag support back with the synthetic bag* in the bag compartment.
Make sure that the HEPA* filter cassette is correctly positioned before closing the cover.
IMPORTANT Never use the vacuum cleaner without a HEPA filter cassette.
For your peace of mind your vacuum cleaner is fitted with a safety system which tells you that the HEPA cassette filter is in place (the cover won’t close unless you’ve put the HEPA) filter cassette in.
4 • Cleaning your vacuum cleaner
Wipe the body of the appliance and the accessories with a soft cloth (Fig.33). Do not use detergents, chemical or abrasive products.
TROUBLESHOOTING
IMPORTANT: As soon as you notice that your vacuum cleaning is not working as well as it should be and before carrying out any checks, switch it off using the On/ Off button.
If your vacuum cleaner won’t start
•The appliance has not got any power: check that the appliance is correctly plugged in.
If your vacuum cleaner doesn’t have any suction power
•An accessory or the flexible hose is blocked: unblock the accessory or the flexible hose.
•The cover won’t close properly: check the positioning of the bag, bag support and HEPA filter cassette and close the cover.
If your vacuum cleaner has less suction power, makes noise, whistles
•An accessory or the flexible hose is partially blocked: unblock the accessory or the flexible hose.
•The bag is full or saturated with fine dust: replace the Wonderbag* bag (18a) or empty the synthetic bag* (18b).
•The filtration system is saturated: change the HEPA* filter cassette (ref
•The mechanical power control switch (20c) is open: close the power nozzle adjustable manual power switch.
GUARANTEE
•This appliance has been designed for domestic use only; the manufacturer will accept no responsibility in the event of any inappropriate use or failure to comply with the instructions and the guarantee will cease to apply.
If the change bag light stays on Red
•The bag is saturated: replace the Wonderbag* bag (18a) or empty the synthetic bag* (18b).
If the cover won’t close (presence sensors 13, 14, 16)
•Check that that the bag support is fitted as well as the bag and that it is positioned correctly.
•Check that the HEPA filter cassette is fitted or that it is correctly positioned.
If the nozzle is difficult to move
•Reduce the power by opening the power nozzle adjustable manual power switch (20c) or by moving the electronic power control (9) to the MIN position.
If the power cord does not rewind completely
•The power cord is slowed down when rewinding: pull the power cord out again and press the power cord rewind button.
If a problem persists, take your vacuum cleaner to your local Tefal Approved Service Centre or contact Tefal Customer Services (you can find contact details on the last page).
•Read the instructions for use carefully before using your appliance for the first time: any use of the appliance which does not conform to these instructions will release Tefal from any liability.
* Depending on models: either equipment specific to cer- |
|