Omega OMG-USB-SER-2 manual SW3, Switch Examples

Models: OMG-USB-SER-2

1 21
Download 21 pages 31.77 Kb
Page 9
Image 9

Configuration

Switch Examples

4851 NE 1

4852 NE 2

SW3

OFF

ON

1

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 2: RS422/485 Interface Configuration

485Mode Selection OFF : 422 Mode

The transmitter lines TX+ and TX- are always driven

ON : 485 Mode

The transmitter lines TX+ and TX- are switched to high impedance when the device is not actively transmitting data

NE 485 option, OFF for 422

OFF : The receiver is always enabled. In a two -wire setup the receiver will echo back all transmitted data.

ON : The receiver is disabled when the transmitter is enabled. In a two-wire setup the receiver will not echo back transmitted data.

Note: Switch positions 1 and 2 are for port 1 and switch positions 3 and 4 for port 2.