CCT-55-I : DC CURRENT INTEGRATOR

ELECTRICAL FEATURES

SIGNAL INPUT

Table 6 indicates two standard available ranges for the CCT-55-I and its electrical specifications. Using the jumpers located on the "MP" input board and "ME" input module, 4 different ranges may be selected ( see Table 7).

For other signal ranges, contact the engineering department for more information.

Reference

A

B

Input range

0 to 5 mAdc

0 to 50 mAdc

Min. input Span *

0.5 mAdc

5 mAdc

 

 

 

Impedance

20

20

TABLE 6

*The minimum input span is the minimum difference between the maximum and minimum input for a full scale output.

Overload100 mAdc 100 mAdc

OUTPUT

FREQUENCY : Pulses per second

0 to 10,000 (12 selectable ranges).

Pulses per hour

0 to 8,790 (13 selectable ranges).

TYPE OF PULSES: Voltage

24 Vdc @ 20 mA maximum.

Sink Current

100 mA. (24 Vdc external power supply)

PULSE WIDTH

100 mS; 50 % of the full cycle or

 

variable with frequency ratio.

ACCURACY

0.2 % FS.

RESPONSE TIME

250 ms.

GALVANIC ISOLATION

Input, Output and Power Supply are all isolated

 

to 2 kVeff. 50 Hz/1 m.

GENERAL SPECIFICATIONS

 

 

STORAGE TEMPERATURE

-30° to +80°C.

OPERATING TEMPERATURE

-10° to +60°C.

TEMPERATURE COEFFICIENT

0.015 %/°C.

STANDARD POWER SUPPLY

115 Vac (±10%) 50/60 Hz.

POWER CONSUMPTION

1.5 VA.

TEST VOLTAGE

4 kVeff. 50 Hz/1m.