CCT-55-V; DC VOLTAGE INTEGRATOR

ELECTRICAL FEATURES

INPUT

Table 4 indicates all the standard available ranges for the CCT-55-V and its electrical specifications. The position of the jumpers are indicated in Fig. 8.

For different signal ranges, contact the engineering department for more information.

Reference

A

B

C

D

E

 

 

 

 

 

 

Range

0 to 100 mV

0 to 1 V

0 to 10 V

0 to 100 V

0 to 650 V

 

 

 

 

 

 

Min. input span *

10 mV

0.1 V

1 V

10 V

100 V

 

 

 

 

 

 

Impedance

100 K

100 K

 

1 M

 

 

 

 

 

 

 

Overvoltage

25 V

75 V

 

1,000 V

 

 

 

 

 

 

 

* The minimum input span is the minimum difference between the maximum and minimum

input for a full scale output.

 

TABLE 4

 

 

OUTPUT

 

 

FREQUENCY : Pulses per second

0 to 10,000 (12 selectable ranges)

Pulses per hour

0 to 8,790 (13 selectable ranges)

TYPE OF PULSES : Voltage

24 Vdc @ 20 mA maximum

Sink Current

100 mA. (24 Vdc external power supply)

PULSE WIDTH

100 ms; 50 % of the full cycle or

 

variable with frequency ratio

ACCURACY

0.2 % FS

RESPONSE TIME

250 ms

GALVANIC ISOLATION

Input, Output and Power Supply are all isolated

 

to 2 kVeff. 50 Hz/1 m.

GENERAL SPECIFICATIONS

 

 

STORAGE TEMPERATURE

-30° to +80°C

OPERATING TEMPERATURE

-10° to +60°C

TEMPERATURE COEFFICIENT

0.015 %/°C

STANDARD POWER SUPPLY

115 Vac (±10%) 50/60 Hz

POWER CONSUMPTION

1.5 VA

TEST VOLTAGE

4 kVeff. 50 Hz/1m.

9

Page 10
Image 10
Omega Engineering CCT-55-I manual CCT-55-V DC Voltage Integrator Electrical Features, Input, Output, General Specifications