Omega Engineering CIO-DAC08, CIO-DAC16 user manual Output Transfer Functions

Models: CIO-DAC08 CIO-DAC16

1 20
Download 20 pages 95 b
Page 15
Image 15

4.2 Output Transfer Functions

To program a DAC, you must select the output you desire in volts, then apply a transfer function to that value. The transfer function for code = output is:

The UNIPOLAR transfer function of the DAC is:

FSV / 4096 * CODE = OutV or CODE = OutV / FSV * 4096

For Example:

If the range is 0 to 5V, and you desire a 2V output CODE = 2/5 * 4096 CODE = 1638

The BIPOLAR transfer function for the DAC is:

FSV/4096 * CODE - 0.5 * FSV or CODE = (OutV + 0.5 * FSV) / FSV * 4096

For example:

If the range is set to ±10 and you desire a −7V output

CODE = (−7V + 0.5 * 20) / 20 * 4096

CODE = 614

11

Page 15
Image 15
Omega Engineering CIO-DAC08, CIO-DAC16 user manual Output Transfer Functions