Omega Engineering CIO-DAC08, CIO-DAC16 user manual HEX Function Range

Models: CIO-DAC08 CIO-DAC16

1 20
Download 20 pages 95 b
Page 7
Image 7

Table 3-1. PC I/O Addresses

HEX

FUNCTION

HEX

FUNCTION

RANGE

 

RANGE

 

 

 

 

 

000-00F

8237 DMA #1

2C0-2CF

EGA

020-021

8259 PIC#1

2D0-2DF

EGA

040-043

8253 TIMER

2E0-2E7

GPIB (AT)

060-063

8255 PPI (XT)

2E8-2EF

SERIAL PORT

060-064

8742 CONTROLLER (AT)

2F8-2FF

SERIAL PORT

070-071

CMOS RAM & NMI

300-30F

PROTOTYPE CARD

 

MASK (AT)

 

 

080-08F

DMA PAGE REGISTERS

310-31F

PROTOTYPE CARD

0A0-0A1

8259 PIC #2 (AT)

320-32F

HARD DISK (XT)

0A0-0AF

NMI MASK (XT)

378-37F

PARALLEL PRINTER

0C0-0DF

8237 #2 (AT)

380-38F

SDLC

0F0-0FF

80287 NUMERIC CO-P

3A0-3AF

SDLC

 

(AT)

 

 

1F0-1FF

HARD DISK (AT)

3B0-3BB

MDA

200-20F

GAME CONTROL

3BC-3B

PARALLEL PRINTER

 

 

B

 

210-21F

EXPANSION UNIT (XT)

3C0-3CF

EGA

238-23B

BUS MOUSE

3D0-3DF

CGA

23C-23F

ALT BUS MOUSE

3E8-3EF

SERIAL PORT

270-27F

PARALLEL PRINTER

3F0-3F7

FLOPPY DISK

2B0-2BF

EGA

3F8-3FF

SERIAL PORT

The CIO-DAC## BASE switch can be set for address in the range of 000-3E0 so it should not be hard to find a free address area for you CIO-DAC##. Once again, if you are not using IBM prototyping cards or some other board which occupies these addresses, then 300-31F HEX are free to use. Address not specifically listed, such as 390-39F, are free.

3

Page 7
Image 7
Omega Engineering CIO-DAC08, CIO-DAC16 user manual HEX Function Range