SYMPTOM

CAUSE

REMEDY

 

Out of fuel

Check fuel level and add fuel if necessary.

 

 

 

 

Fuel filter restricted.

Change fuel filter.

 

 

a. Engine collant level low; add coolant.

 

 

b. Compressor oil and radiator flow

 

 

restricted; clean coolers.

 

 

c. Fan belts slipping or broken; repair or

Machine shuts

Safety shutdown switches

replace.

d. Compressor oil low; add oil.

down with air

activated.

e. Engine oil level low; add oil.

demand present.

 

 

f. Compressor oil filter restricted; change

 

 

 

 

the filter.

 

 

g. Engine oil filter restricted; change the

 

 

filter.

 

Defective safety shutdown

Check the shutdown switches.

 

switch.

 

 

 

Thermostatic valve

Clean or replace the thermostatic

 

malfunctioning.

element.

 

Defective gauge.

Replace the gauge.

 

Air demand too great.

Check service lines for leaks or open

Machine will not

valves.

 

 

a. Check to see fit the blowdown valve is

build up pressure

Blowdown valve open.

getting a pilot signal.

 

 

b. Repair or service valve.

 

Faulty coupling.

Replace the coupling.

 

Defective gauge.

Replace the gauge.

With no demand

Air cylinder not fully

a. Check for restrictions in the control

lines.

the compressor

extending.

 

b. Repair or replace control air cylinder.

builds excessive

 

 

 

c. Check that the inlet valve is closing.

pressure.

 

Pressure regulator not

a. Adjust the regulator

 

 

properly adjusted or faulty.

b. Repair or replace the regulator.

 

Compressor undersized for

Recheck maximum air requirement.

 

the air requirement.

 

 

 

Engine speed low.

Check speed and adjust as necessary.

Insufficent air

 

a. Check air filter for dirt and make sure

 

the indicator is working.

delivery

Air intake restricted

b. Look for obstructions in the filter and

 

inlet piping.

 

 

 

 

c. Check that the inlet valve is opening

 

 

fully.

 

Faulty drive coupling.

Replace the coupling.