SYMPTOM

CAUSE

REMEDY

 

Oil reserve over filled.

Drain to the proper level.

 

Leak in the compressor oil

Check all piping lines and connections;

 

system.

repair as necessary.

Excessive

Oil scavenge line not removing

a. Check scavenge line and its check

valve for restrictions; clear as necessary.

compressor oil

the oil from the separator.

b. Make sure that the scavenge line

consumption.

 

reaches the bottom of the separator.

 

Separator element damaged.

Replace the element.

 

Compressor undersized for

Operating at low pressures increases the

 

oil carry over; recheck the load

 

the air requirement.

 

requirements.

 

 

 

Unit being operating in an

Reposition the unit or open up the

 

area with limited fresh air.

confinement.

 

Fan belts are loose or broken.

Tighten or replace.

 

 

 

 

Dirt build up on the coolers.

Clean the cooler thoroughly. Be careful

 

not to damage the fins.

 

 

 

Compressor level low.

Check and fill to proper level.

Compressor

Compressor oil filter dirty.

Replace the filter.

Thermostatic valve

 

overheating

Clean or replace the element.

malfunctioning.

 

 

 

Restriction in the compressor

Clean or replace the lines.

 

oil lines.

 

 

Restriction inside the oil

Clean internal tubes of the cooler.

 

cooler.

 

 

 

Operating the compressor

Reinstall panels.

 

with the panels removed.

 

 

 

Coolant level low.

Add coolant to the proper level.

 

Leaks in the fuel system.

Check all the fuel lines and connections;

 

repair or replace as necessary.

 

 

 

Engine not at correct

Adjust the engine to its proper speed.

 

operating speed.

 

 

High fuel

Pressure to regulator set too

Adjust regulator to correct pressure for the

high.

unit.

consumption

 

Inspect the air intake system checking for

 

 

 

Engine air intake is restricted.

any restriction; clean repair or replace as

 

 

necessary.

 

Incorrect injection timing.

Adjust to specifications in the engine

 

manual.

 

 