■Interrupt Input Units

Unit classification

CJ

Basic

I/O

Units

 

 

 

 

 

 

 

 

Current

 

 

 

 

 

Specifications

 

 

 

consumption

 

 

Product

 

 

 

 

 

 

No. of

 

(A)

 

 

 

 

 

Input

 

 

words

 

 

 

Model

Standards

name

 

Input

 

Max. Units

 

 

 

 

I/O

 

pulse

External

allocated

 

 

 

 

 

 

voltage

Commons

mountable

5 V

 

24 V

 

 

 

points

width

connection

 

 

 

 

 

 

current

 

conditions

per Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Interrupt

 

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

ON time:

 

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.05 ms

 

Removable

 

 

 

 

 

 

 

16

24 VDC,

16 point,

 

 

 

 

 

 

 

 

max.

2

terminal

1 word

0.08

 

CJ1W-INT01

UC1, N, L, CE

 

outputs

7 mA

1 common

 

 

OFF time:

 

block

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0.5 ms max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note 1. Can be used only on CPU Racks, and not on Expansion Racks.

2.The locations where the Units can be mounted depend on the CPU Rack and the CPU Unit model. CJ1G, CJ1H: From the slot next to the CPU Unit until the fifth slot.

CJ1M: From the slot next to the CPU Unit until the third slot.

■High-speed Input Units

Unit classification

CJ

Basic

I/O

Units

 

 

 

 

 

 

 

Current

 

 

 

 

 

Specifications

 

No. of

consumption

 

 

Product

 

 

 

 

 

 

(A)

 

 

 

 

 

 

 

words

 

Model

Standards

name

 

 

 

Input pulse

 

 

 

 

I/O

Input voltage,

 

External

allocated

 

 

 

 

 

 

Commons

width

5 V

 

24 V

 

 

 

points

Input current

connection

 

 

 

 

 

 

 

 

conditions

 

 

 

 

 

 

 

High-

 

 

 

 

 

 

 

 

 

 

 

speed

 

 

 

 

 

 

 

 

 

 

 

Input

 

 

 

ON time:

 

 

 

 

 

 

 

Unit

 

 

 

 

 

 

 

 

 

 

16

 

16 point,

0.05 ms max.

Removable

 

 

 

 

 

 

 

24 VDC, 7 mA

1 word

0.08

 

CJ1W-IDP01

UC1, N, L, CE

 

outputs

1 common

OFF time: 0.5

terminal block

 

 

 

 

 

 

 

 

 

 

 

 

 

ms max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: There are no restrictions on the mounting position or number of Units.

■B7A Interface Units

Unit

classification

Product

 

 

 

 

name

 

 

B7A

 

 

Interface

CJ

 

Units

Basic

 

I/O

 

 

Units

 

 

 

 

 

Specifications

 

Current

 

 

 

 

consumption (A)

 

 

 

 

 

 

 

 

 

 

 

No. of words

 

 

Model

Standards

 

 

 

allocated

 

 

I/O points

 

External connection

5 V

24 V

 

 

 

 

 

 

64 inputs

 

 

 

0.07

CJ1W-B7A14

 

 

 

 

 

 

 

 

 

64 outputs

 

Removable terminal block

4 words

0.07

CJ1W-B7A04

UC1, CE

 

 

 

 

 

 

 

 

32 inputs/outputs

 

 

 

0.07

CJ1W-B7A22

 

 

 

 

 

 

 

 

 