Performance Specifications

 

 

 

 

 

 

 

Item

 

Logical Ports for

 

Logical Ports

 

 

 

Communications

 

Extended Logical Ports

 

 

 

 

 

 

 

 

Cip

 

 

 

 

Class 3

 

Communications

 

(Number of Connections)

 

Specification

 

UCMM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(Non-connection Type)

 

Peripheral (USB) Port

 

 

Baud Rate

 

 

 

 

 

 

 

 

Transmission Distance

 

Serial Port

 

 

 

 

Communications Method

 

 

 

 

Synchronization Method

 

 

Baud Rate

 

 

 

 

Transmission Distance

 

EtherNet/IP Port

 

 

 

 

Specifications

 

Media Access Method

 

 

 

 

 

 

Modulation

 

 

 

 

 

 

 

 

Transmission Paths

 

 

 

 

Baud Rate

 

 

Transmission

 

Transmission Media

 

 

 

Transmission Distance

 

 

 

 

 

 

 

 

Number of Cascade Connections

 

 

SpecificationsCommunication

 

CIP Communications: Tag Data Links

Communications

 

 

 

Number of Connections

 

 

 

 

 

 

 

 

Packet Interval (Refresh period)

 

 

 

 

 

Permissible Communications Band

 

 

 

 

 

Number of Tag Sets

 

 

 

 

 

Type of Tags

 

 

 

 

 

Number of Tags per Connection

 

 

 

 

 

Maximum Link Data Size per Node

 

 

 

 

 

Maximum Data Size per Connection

 

 

 

 

 

Number of Registrable Tag Set

 

 

 

 

 

Maximum Tag Set Size

 

 

 

 

 

Maximum Number of Tags Refreshable in

 

 

 

 

 

a Single Cycle of CPU Unit (See note 3.)

 

 

 

 

 

Data Size Refreshable in a Single Cycle

 

 

 

 

 

of CPU Unit (See note 3.)

 

 

 

 

 

Change of Tag Data Link Parameter

 

 

 

 

 

Settings during Operation

 

 

 

 

 

Multi-cast Packet Filter (See note 5.)

 

 

 

 

CIP Communications: Explicit Messages

 

 

 

 

 

Class 3 (Number of Connections)

 

 

 

 

 

 

 

 

 

 

UCMM (Non-connection Type)

 

 

 

 

 

CIP Routing

 

 

 

 

FINS Communications

 

 

 

 

 

FINS/UDP

 

 

 

 

 

 

 

 

 

 

FINS/TCP

 

 

 

 

EtherNet/IP Conformance Test

 

 

 

 

EtherNet/IP Interface

 

 

 

 

 

 

 

 

CJ2H-

CPU64-EIP

CPU65-EIP

CPU66-EIP

CPU67-EIP

CPU68-EIP

 

 

 

 

 

8 ports (Used for SEND, RECV, CMND, PMCR, TXDU, and RXDU instructions.)

64 ports (Used for SEND2, RECV2, CMND2, and PMCR2 instructions.)

Number of connections: 64

Maximum number of clients that can communicate at the same time: 32

Maximum number of servers that can communicate at the same time: 40

USB 2.0-compliant B-type connector

12 Mbps max.

5 m max.

Interface: Conforms to EIA RS-232C.

Half-duplex

Start-stop

0.3, 0.6, 1.2, 2.4, 4.8, 9.6, 19.2, 38.4, 57.6, or 115.2 (kbps)

15 m max.

CSMA/CD

Baseband

Star

100 Mbps (100Base-TX)

Shielded twisted-pair (STP) cable; Categories: 5, 5e

100 m (between hub and node)

No restrictions if switching hub is used.

256

0.5 to 10,000 ms (Unit: 0.5 ms)

Can be set for each connection. (Data will be refreshed at the set interval, regardless of the number of nodes.)

6,000 pps (See note 1.)

256

CIO, DM, EM, HR, and WR

8 (Seven tags if PAC status is included in the segment.)

184,832 words

252 or 722 words (See note 2.)

(Data is synchronized within each connection.)

256 (1 connection = 1 segment)

722 words (One word is used when PAC status is included in the segment.)

Output/send (CPU Unit to EtherNet/IP): 256

Input/receive (EtherNet/IP to CPU Unit): 256

Output/send (CPU to EtherNet/IP): 6,432 words

Input/receive (EtherNet/IP to CPU): 6,432 words

OK (See note 4.)

OK

Number of connections: 128

Maximum number of clients that can communicate at the same time: 32

Maximum number of servers that can communicate at the same time: 32

OK (CIP routing is enabled for the following remote Units: CJ1W-EIP21 and CJ2H-CPU6-EIP.)

OK

16 connections max.

Conforms to A5.

10Base-T/100Base-TX

Auto Negotiation/Fixed Setting

Note 1. “Packets per second” is the number of communications packets that can be processed per second.

2.Large Forward Open (CIP optional specification) must be supported in order for 505 to 1,444 bytes to be used as the data size. Application is supported between CS/CJ-series PLCs. When connecting to devices from other manufacturers, make sure that the devices support the Large Forward Open specification.

3.If the maximum number is exceeded, refreshing will require more than one CPU Unit cycle.

4.When changing parameters, however, the EtherNet/IP port where the change is made will be restarted. In addition, a timeout will temporarily occur at the other node that was communicating with that port, and it will then recover automatically.

5.The EtherNet/IP port supports an IGMP client, so unnecessary multicast packets are filtered by using a switching hub that supports IGMP snooping.

22

Page 22
Image 22
Omron CJ2 manual Ucmm, Fins/Udp, Fins/Tcp, Csma/Cd

CJ2 specifications

The Omron CJ2 series is a powerful and versatile family of programmable logic controllers (PLCs) that exemplify modern automation technology. Known for their robust performance and reliability, CJ2 controllers are widely used in various industries for controlling machinery, processes, and other automated systems.

One of the main features of the CJ2 series is its impressive scalability. The platform offers various models, allowing users to choose the right controller based on their application needs. The CJ2 series supports up to 64 I/O modules, providing ample flexibility for expanding system capabilities. Additionally, it supports more than 4096 I/O points with the right configuration, making it suitable for small to large-scale applications.

The CJ2 series leverages Omron's advanced Kinematics technology, which enhances motion control capabilities. This feature is particularly beneficial for applications requiring precise control over moving parts, such as robotics and material handling systems. The CJ2 can manage multiple axes simultaneously, allowing for complex multi-axis systems to be programmed easily.

Another key characteristic of the CJ2 is its high-speed processing. The controller is equipped with a fast CPU that delivers quick execution of logic programs and supports high-speed data processing, making it ideal for time-critical applications. The CJ2 series also incorporates a rich instruction set that supports various programming languages, including ladder diagram, structured text, and function block diagram, catering to the preferences and needs of different programmers.

Enhanced communication capabilities are another highlight of the Omron CJ2 series. It supports various fieldbus protocols, including Ethernet/IP, Profibus, and DeviceNet, allowing for seamless integration with other devices and systems. This connectivity enables users to build complex, coordinated systems that communicate effectively in real-time.

The CJ2 series also boasts robust diagnostics features, making it easier to troubleshoot and maintain installations. The controller can store extensive diagnostic information, helping users quickly identify issues within the system. Additionally, the CJ2's user-friendly programming environment simplifies the development process, allowing for rapid deployment.

In summary, the Omron CJ2 series stands out for its scalability, advanced motion control capabilities, high-speed processing, and enhanced communication features. These characteristics make it a go-to option for engineers and manufacturers seeking a reliable and flexible PLC solution to meet their automation needs. Its combination of performance, versatility, and user-friendly design cements the CJ2's reputation as a leader in the field of industrial automation.