Performance Specifications

 

Item

 

 

 

CJ2H-

 

 

 

CPU64-EIP

 

CPU65-EIP

CPU66-EIP

CPU67-EIP

CPU68-EIP

 

 

 

Programming Languages

Ladder Logic (LD),

 

 

 

 

 

 

Sequential Function Charts (SFC),

 

 

 

 

 

Structured Text (ST), and

 

 

 

 

 

 

Instruction Lists (IL)

 

 

 

 

 

 

 

 

 

 

 

 

Function Blocks

Maximum number of definitions

2,048

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Maximum number of instances

2,048

 

 

 

 

 

 

 

 

 

 

 

 

Tasks

Type of Tasks

Cyclic tasks

 

 

 

 

 

 

Interrupt tasks (Power OFF interrupt tasks, scheduled interrupt tasks, I/O interrupt tasks, and

 

 

 

external interrupt tasks)

 

 

 

 

 

 

 

 

 

 

 

 

Number of Tasks

Cyclic tasks: 128

 

 

 

 

 

 

Interrupt tasks: 256

 

 

 

 

 

 

(Interrupt tasks can be defined as cyclic tasks to create extra cyclic tasks. Therefore, the total

 

 

 

number of cyclic tasks is actually 384 max.)

 

 

 

 

 

 

 

 

Symbols

Type of Symbols

• Local symbols: Can be used only within a single task in the PAC.

 

 

(Variables)

 

• Global symbols: Can be used in all tasks in the PAC.

 

 

 

 

• Network symbols (tags): I/O memory in the CPU Unit can be externally accessed using symbols, depending on

 

 

parameter settings.

 

 

 

 

 

 

 

 

 

 

 

 

Data Type of Symbols

• BOOL (bit)

 

 

 

 

UINT (one-word unsigned binary)

UDINT (two-word unsigned binary)

ULINT (four-word unsigned binary)

UINT BCD (one-word unsigned BCD)

INT (one-word signed binary)

DINT (two-word signed binary)

LINT (four-word signed binary)

UDINT BCD (two-word unsigned BCD)

ULINT BCD (four-word unsigned BCD)

REAL (two-word floating-point)

LREAL (four-word floating-point)

CHANNEL (word)

NUMBER (constant or number)

WORD (one-word hexadecimal)

DWORD (two-word hexadecimal)

LWORD (four-word hexadecimal)

TIMER

COUNTER

 

Maximum Size of Symbol

32k words

 

 

 

 

 

 

 

 

 

 

Array Symbols (Array Variables)

One-dimensional arrays

 

 

 

 

 

 

 

 

 

 

Number of Array Elements

32,000 elements max.

 

 

 

 

 

 

 

 

 

 

Number of Registrable Network

20,000 max.

 

 

 

 

Symbols (Tags)

 

 

 

 

 

 

 

 

 

 

 

Length of Network Symbol (Tag)

255 bytes max.

 

 

 

 

Name

 

 

 

 

 

 

 

 

 

 

 

Encoding of Network Symbols

UTF-8

 

 

 

 

(Tags)

 

 

 

 

 

 

 

 

 

 

Data Tracing

Memory Capacity

8,000 words

16,000 words

 

32,000 words

 

 

 

 

 

 

 

 

(Up to 32k words x 25 banks when EM is specified in CX-Programmer)

 

 

 

 

 

 

Number of Samplings

Bits = 31, one-word data =16, two-word data = 8, four-word data = 4

 

 

 

 

 

 

 

 

Sampling Cycle

1 to 2,550 ms (Unit: 1 ms)

 

 

 

 

 

 

 

 

 

 

Trigger Conditions

ON/OFF of specified bit

 

 

 

 

 

Data comparison of specified word

 

 

 

 

 

Data size: 1 word, 2 words, 4 words

 

 

 

 

 

Comparison Method: Equals (=), Greater Than (>), Greater Than or Equals (), Less Than (<), Less Than or Equals

 

 

(), Not Equal ()

 

 

 

 

 

 

 

 

 

 

Delay Value

−32,768 to +32,767 ms

 

 

 

 

 

 

File Memory

 

Memory Card (128, 256, or 512 Mbytes) (Use the Memory Cards provided by OMRON.)

 

 

EM file memory (Part of the EM Area can be converted for use as file memory.)

 

 

 

 

 

 

Source/Comment

Function block program memory,

Capacity: 3.5 Mbytes

 

 

 

Memory

comment file, program index file,

 

 

 

 

 

symbol tables

 

 

 

 

 

 

 

 

 

 