4 = TEST (SYSTEM DIAGNOSTIC TEST)

The diagnostic test performed by the HMS 1100 allows you to check the status of the battery, telephone, bell circuit, auxiliary fuse, and security zone loop readings. The display is updated 3 times per second, although the actual readings are taken 10 times per second. To enter the Test menu, from the Status menu, press the 4 (TEST) key on the console keypad.

The first display shows the current battery reading and the phone line status. A battery test is initiated when the status mode is first entered. The new battery reading is updated ten seconds later. The low battery limit is also displayed.

The phone status consists of two parts, separated by a "/". The first part shows the current phone line state:

ONHK - ON HOOK

OFFHK - OFF HOOK

RING - RINGING

DEAD - DEAD PHONE LINE

The second part shows how the HMS 1100 is currently using the phone line:

IDLE - NOT USING THE PHONE LINE

LOCAL - LOCAL ACCESS

REMOTE - REMOTE ACCESS

VOICE - IN VOICE DIAL OUT MODE

EMGACC - ACCESS AFTER VOICE DIAL OUT

DCM - IN DIGITAL COMMUNICATOR MODE

BATTERY:

230 (LIMIT 200)

PHONE:

ONHK/IDLE

Next, the display shows the A/D reading for the battery voltage, phone line voltage, AC power on, bell, and fuse:

BAT:

225

PHONE: 140

ACON:

82

BELL: 215

FUSE: 222

The next series of displays shows the current analog reading for each security zone input. The displays show the readings for zones 1-176.

1=147 2=148 3=147 4=146 5=146 6=147 

THROUGH

175=148 176=147

Normal readings for zones are between 137 - 157 when secure. If Zones 1-4 are configured as Fire or Gas zone, normal readings are between 26 - 43 when secure. Each reading should be changing only by two or three counts from its average steady reading. When a door or window is opened, the reading will go up to a value that represents that zone is open.

This feature can be used to monitor the quality of the zone wiring and contacts. If the numbers begin to deviate from their original values when the system was new, wiring problems that will eventually lead to trouble or false alarms may be developing. You may wish to record the Status Test values for future reference.

5 = TEMP (TEMPERATURE)

The Temperature Status menu allows you to view and scroll through the status of each Thermostat and Temperature Sensor. To enter the Temperature menu, from the Status menu, press the 5 key on the console keypad. The system will display:

TSTAT 1

TEMP:80

HEAT:60

COOL:82

 

Page 28