Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

 

Scanner Timeout (Trigger Enabled

 

Mode)

Y1

1 second after triggering

Y2

2 second after triggering

Y3

3 second after triggering

Y4

4 second after triggering

Y5

5 seconds after triggering

Y6

6 second after triggering

Y7

7 seconds after triggering

Y8

8 seconds after triggering

Y9

9 seconds after triggering

YL

Read time x 10

YM

Indefinitely after triggering

 

 

XA

Add-on Wait Time - Disable

XB

Add-on Wait Time – 250 msec

XC

Add-on Wait Time – 500 msec

XD

Add-on Wait Time – 750 msec

 

 

AH

Multiple Read Reset Time – 50 msec

AI

Multiple Read Reset Time – 100 msec

AJ

Multiple Read Reset Time – 200 msec

AK

Multiple Read Reset Time – 300 msec

AL

Multiple Read Reset Time – 400 msec

AM

Multiple Read Reset Time – 500 msec

AN

Multiple Read Reset Time – 600 msec

AG

Multiple Read Reset Time - Indefinite

 

 

 

Quiet Zone Options

YN

No margin check

YO

Margin check 1/7 nominal

YP

Margin check 2/7 nominal

YQ

Margin check 3/7 nominal

YR

Margin check 4/7 nominal

YS

Margin check 5/7 nominal

YT

Margin check 6/7 nominal

YU

Margin check normal

 

 

 

Redundant Decoding

X0

Read bar code once

X1

Read bar code twice before transmitting

X2

Read bar code three times before transmitting

X3

Read bar code four times before transmitting

BS

Read bar code five times before transmitting

BT

Read bar code six times before transmitting

BU

Read bar code seven times before xmitting

BV

Read bar code eight times before xmitting

BW

Read bar code nine times before xmitting

 

 

 

Xmit Error (Trigger Enabled Mode only)

TH

User defined error message for no label

TI

User defined error message for no decode

TG

Clear error messages for no label, no decode

 

 

WD

Response to command - None

WC

Response to command – OK=ACK,

 

ERROR=NAK

 

 

WB

Buzzer Control to Command - Disable

WA

Buzzer Control to Command - Enable

 

 

 

Good Read LED Operation

T4

Disable good read LED (GRL)

T5

GRL ON for 0.20 seconds after decode

T6

GRL ON for 0.40 seconds after decode

T7

GRL ON for 0.80 seconds after decode

Page 23

Page 27
Image 27
Opticon LMD 1135 Scanner Timeout Trigger Enabled, Mode, Quiet Zone Options, Redundant Decoding, Good Read LED Operation