Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 4

Configuring the Scanner

Since the operation of the LMD 1135 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways.

1.The scanner can be programmed by sending software instructions from the host PC to the scanner via the RS232 connection.

2.The second method employs specially designed programming bar codes. Scanning these bar codes instructs the scanner to modify specific parameters.

Programming Menus & Commands

Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the computer commands and programming bar codes that are available to customize the scanner for your application.

Default Settings

When you modify or change any parameters, the scanner can be programmed to retain the new parameter in memory, even if power interrupted or terminated. If for any reason the scanner is instructed to return all parameters to default settings (U2), it will return to the default settings shown in the following table.

Default settings are indicated by a pointing hand symbol (%) throughout the bar codes menus.

Parameter

Factory Default Setting

RS 232 Communications

9600 baud

 

 

8 data bits

 

 

1 stop bit

 

 

No parity

 

 

No handshaking

Trigger Function

Enabled

Auto-Trigger Function

Enabled

Read Mode

Multiple Read Mode

No. of Redundant Decodes

Read three times before transmitting

UPC-A

(12 digits)

No leading zero

 

 

Enable check digit

UPC-E

(7 digits)

No leading zero

 

 

Enable check digit

Code 39

Do not calculate check digit/Transmit check digit

 

 

Disable start/stop characters (*.....*)

Codabar

Disable start/stop characters

 

 

Do not calculate check digit

2 of 5 (Interleaved and

Do not calculate check digit

Industrial)

 

Fixed length of bar code only

Disabled

Buzzer

 

Enabled

Positive bar codes only

Enabled

Error indications

Do not transmit error code