Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

35. Transmitting Error Indications (Trigger Enabled only)

Computer

Function

Bar Code

 

Command

/Description

Command

 

(ZZ)

START/END

[[

￿

Programming Menu

 

 

 

 

TH

Error message no label

UI

￿

 

 

 

 

 

TI

Error message no decode

UJ

￿

 

 

 

 

 

TG

Clear error messages for no label

UH

￿

and no decode

 

 

 

 

WD

Disable response to command

XE

￿

 

 

 

 

 

WC

Enable response to command

XD

￿

OK=ACK, ERROR=NAK

 

 

 

 

WB

Buzzer Control to Command –

XC

￿

Disable

 

 

 

 

WA

Buzzer Control to Command –

XB

￿

Enable

 

 

 

 

Error Messages – No decode / no label

￿

￿

￿

￿

%￿

￿

￿

%￿

Messages may be user defined for the “no decode” and “no label” error modes independently. Using the “Error message no label” (TH) and “Error message no decode” (TI) menu commands a maximum of 4 characters may be user specified for transmission should these errors occur.

The following process should be followed to designate these error codes:

1.Scan “START” to enter the programming mode.

2Scan “Error message no label” (TH).

3.Scan bar codes of the desired error message characters (4 max)

4.Scan “END” to end the programming sequence.

In a similar fashion, the “Error message no decode” (TI) can be defined.

Page 65