Manual No. | NFT 2100 CCD Fixed Mount Barcode |
Scanner |
|
| Communication Handshaking | |
|
| |
P1 | Busy/Ready | |
|
| |
P2 | Modem | |
|
| |
P3 | ACK/NAK (1 sec timeout with error buzzer) | |
|
| |
P4 | ACK/NAK no response (100 ms timeout, | |
terminates with good read buzzer) | ||
| ||
|
| |
ZG | XON/OFF | |
|
|
| Communication Delays |
|
|
KA | No intercharacter delay |
KB | 20 ms intercharacter delay |
|
|
KC | 50 ms intercharacter delay |
|
|
KD | 100 ms intercharacter delay |
|
|
| Buzzer Operation |
|
|
T0 | Volume = Maximum |
T1 | Volume = Upper |
|
|
T2 | Volume = Lower |
|
|
T3 | Volume = Minimum |
|
|
W0 | Disable Buzzer |
|
|
W1 | Enable buzzer at 3kHz |
|
|
W2 | Enable buzzer at 3kHz with 2.5kHz interval |
W3 | Enable buzzer at 3kHz with 4kHz interval |
|
|
W4 | Buzzer duration 0.10 sec |
|
|
W5 | Buzzer duration 0.20 sec |
W6 | Buzzer duration 0.40 sec |
|
|
W7 | Buzzer duration 0.05 sec |
|
|
W8 | Enable buzzer |
|
|
| Setting the Trigger Functions | |
|
| |
S7 | Disable the trigger function (LED On) | |
S8 | Enable the trigger function (LED OFF until the | |
trigger is activated ) | ||
|
ZActivate the trigger; turns the LEDs ON
Y Terminate the trigger.
| Selecting the Read Mode | |
|
| |
S0 | Single Read Mode (Trigger must be Enabled, | |
S8) | ||
| ||
|
|
S1 | Multiple Read Mode | |
S2 | Continuous Read Mode | |
|
| |
|
| |
| Scanner Timeout (Trigger Mode) | |
|
| |
Y1 | 1 second after triggering | |
|
| |
Y2 | 2 second after triggering | |
Y3 | 3 second after triggering | |
|
| |
Y4 | 4 second after triggering | |
|
| |
Y5 | 5 seconds after triggering | |
|
| |
Y6 | 6 second after triggering | |
|
| |
Y7 | 7 seconds after triggering | |
|
| |
Y8 | 8 seconds after triggering | |
|
| |
Y9 | 9 seconds after triggering | |
|
| |
YL | Read time x 10 | |
|
| |
| Scan time follows Hardware trigger active | |
Y0 | time. Can be terminated by sending the Y | |
| command | |
|
| |
YM | Stays ON indefinitely after triggering. Must be | |
terminated by sending the Y commands. | ||
| ||
|
| |
|
| |
| EAN/UPC Add On Wait Times | |
|
| |
XA | ||
|
| |
XB | ||
|
| |
XC | ||
XD | ||
|
| |
|
| |
| S1 Multiple read reset time for same | |
| labels | |
|
| |
AH | Multiple Read Reset Time – 50 msec | |
|
| |
AI | Multiple Read Reset Time – 100 msec | |
|
| |
AJ | Multiple Read Reset Time – 200 msec | |
|
| |
AK | Multiple Read Reset Time – 300 msec | |
|
| |
AL | Multiple Read Reset Time – 400 msec | |
|
| |
AM | Multiple Read Reset Time – 500 msec | |
AN | Multiple Read Reset Time – 600 msec | |
|
| |
AG | Multiple Read Reset Time - Indefinite | |
|
| |
|
| |
| Quiet Zone Options | |
|
| |
YN | No margin check | |
|
|
Page 21