Manual No. | NFT 2100 CCD Fixed Mount Barcode |
Scanner |
|
Section 4 |
|
Configuring the Scanner |
|
Since the operation of the NFT 2100 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways.
1.The scanner can be programmed by sending software commands from the host PC to the scanner via the RS232 connection. Most commands will be immediately active, but are not stored into non- volatile memory until the store command, Z2, is sent. A few commands, such as changing the communication parameters will not be active until they are stored via the Z2 command.
2.The second method employs specially designed programming bar codes referred to as menu commands. Scanning these bar codes instructs the scanner to modify specific parameters. These commands are stored into
Programming Menus & Commands
Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the computer commands and programming bar codes that are available to customize the scanner for your application.
Default Settings
When you modify or change any parameters, the scanner can be programmed to retain the new parameter in
Default settings are indicated by a pointing hand symbol (%) throughout the bar codes menus.
Parameter | Factory Default Setting | ||
|
| 9600 baud | |
RS 232 Communications | 8 data bits | ||
1 stop bit | |||
|
| No parity | |
|
| No handshaking | |
Trigger Function | Disabled, (scanner is ON) | ||
Read Mode | Multiple Read Mode | ||
No. of Redundant Decodes | Read three times before transmitting | ||
(12 digits) | No leading zero transmitted (EAN 1st Position) | ||
send check digit | |||
|
| ||
| (7 digits) | No leading zero transmitted | |
Send check digit | |||
|
| ||
Code 39 | Do not calculate check digit/Transmit check digit | ||
Disable start/stop characters transmission (*.....*) | |||
|
| ||
Codabar | Disable start/stop characters transmission | ||
Do not calculate check digit | |||
|
| ||
2 of 5 (Interleaved & Industrial) | Do not calculate check digit | ||
Min/Max length of bar code only | Disabled | ||
Buzzer |
| Enabled | |
Positive bar codes only | Enabled | ||
Error indications | Do not transmit error message | ||
Suffix |
| Carriage Return |
Page 12