Since the operation of the NFT 2100 scanners are microprocessor controlled, it is possible to modify or program its operation to match your specific application. Changes in parameter settings can be accomplished two ways.

1.The scanner can be programmed by sending software commands from the host PC to the scanner via the RS232 connection. Most commands will be immediately active, but are not stored into non- volatile memory until the store command, Z2, is sent. A few commands, such as changing the communication parameters will not be active until they are stored via the Z2 command.

2.The second method employs specially designed programming bar codes referred to as menu commands. Scanning these bar codes instructs the scanner to modify specific parameters. These commands are stored into non-volatile memory as soon as the menu command mode is exited. Once stored in non-volatile memory, these settings will remain even after powering the unit OFF and ON.

Programming Menus & Commands

Appendix A contains full instructions on how to configure the scanner as well as a complete listing of the computer commands and programming bar codes that are available to customize the scanner for your application.

Default Settings

When you modify or change any parameters, the scanner can be programmed to retain the new parameter in non-volatile memory, even if power is interrupted or terminated. If for any reason the scanner is instructed to return all parameters to default settings (U2), it will return to the default settings shown in the following table.

Default settings are indicated by a pointing hand symbol (%) throughout the bar codes menus.

Parameter

Factory Default Setting

 

 

9600 baud

RS 232 Communications

8 data bits

1 stop bit

 

 

No parity

 

 

No handshaking

Trigger Function

Disabled, (scanner is ON)

Read Mode

Multiple Read Mode

No. of Redundant Decodes

Read three times before transmitting

UPC-A

(12 digits)

No leading zero transmitted (EAN 1st Position)

send check digit

 

 

UPC-E

(7 digits)

No leading zero transmitted

Send check digit

 

 

Code 39

Do not calculate check digit/Transmit check digit

Disable start/stop characters transmission (*.....*)

 

 

Codabar

Disable start/stop characters transmission

Do not calculate check digit

 

 

2 of 5 (Interleaved & Industrial)

Do not calculate check digit

Min/Max length of bar code only

Disabled

Buzzer

 

Enabled

Positive bar codes only

Enabled

Error indications

Do not transmit error message

Suffix

 

Carriage Return

Page 12