Opticon

OPR 2001

Specifications Manual

13.Durability

13.1.Electrical Noise

No malfunction occurred when sinusoidal electrical noise (10Hz -100kHz, < 0.1Vpp) was added to a power supply line.

Conditions

Barcode Sample: OPTOELECTRONICS Test Sample

PCS:

0.9

Resolution:

0.25 mm

Symbology:

9-digit Code-39

Quiet Zone:

10 mm

N/W Ratio:

1:2.5

Distance:

90 mm

Angle:

α = 0° β = 15° γ = 0°

Curvature:

R = ∞

Power Supply Voltage:

5.0 V

13.2.Shock

13.2.1.Drop Test (without packaging)

No malfunction occurred after the following drop test.

Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor three times on each of 5 sides.

Figure 26: Drop test

13.2.2.Drop Test (with individual packaging)

No malfunction occurred after the following drop test.

Drop Test: Drop the scanner from a height of 150 cm onto a concrete floor on each of one corner, three edges, and six sides (10 drop tests in total).

35

Page 35
Image 35
Opticon OPR 2001 Durability, Electrical Noise, Shock Drop Test without packaging, Drop Test with individual packaging