10.3. Default Settings 2: Read Options, Trigger, Buzzer

Item

Default Setting

 

 

 

Setting the number of characters

Fixed length OFF all codes

 

 

 

Read mode

Single read

 

 

 

Multiple read reset time

500 ms

 

 

 

Add-on wait time

500 ms

 

 

 

Multiple columns read

Disabled

 

 

 

 

Default option

Read 1 times, redundancy = 0

 

([X0] setting)

 

 

 

 

 

Other options

Read n times, redundancy = n+1

 

([X1 .. X3] setting)

for following symbologies and lengths:

 

([BS .. BW] setting)

● Code39 with length <= 5

Redundancy

 

● MSI/Plessey with length <= 4

 

● IATA,Industrial 2of5, Interleaved 2of5

 

 

with length <= 8

 

 

● Matrix 2of5 (& Chin.Post), Scode

 

 

with length <= 8

 

 

● Codabar (NW7) with all lengths

 

 

Code-11 with length <= 5

 

 

 

Trigger switch

Enabled

 

 

Trigger repeat

Disable trigger repeat

 

 

Auto trigger

Disable auto trigger

 

 

Margin check

Margin check normal

 

 

Buzzer duration

50 ms

 

 

Buzzer tone

3 kHz (single tone)

 

 

Buzzer loudness

Loud (Maximum)

 

 

Buzzer timing

Buzzer before transmission

 

 

Startup buzzer

Enable startup buzzer

 

 

Indicator duration

200 ms

 

 

 