Function

E6581301

5.20Standard default setting

￿￿￿

: Factory default setting

Function

This parameter is to set two or more parameters at a time for different commands. Using this parameter, all parameters can be also return to their respective default settings by one operation, and save or set specific parameters individually.

Title

Adjustment range

Default setting

 

 

 

￿: –

 

 

 

 

 

￿:50Hz default setting

 

 

 

 

 

￿:60Hz default setting

 

 

 

 

 

￿:Factory default setting

 

 

 

 

 

￿:Trip clear

 

 

 

 

Factory default

￿:Cumulative operation time cleared

 

 

 

￿￿￿

￿:Initialization of type information

 

￿

 

setting

 

 

 

￿:Save user-defined parameters

 

 

 

 

 

 

 

 

 

 

￿:Reset of user-defined parameters

 

 

 

 

 

￿:Cumulative fan operation time record clear

 

 

 

 

 

￿￿:Acceleration/deceleration time setting 0.01 sec.~600.0

 

 

 

 

 

sec. [Note 4]

 

 

 

 

 

￿￿:Acceleration/deceleration time setting 0.1 sec.~6000 sec.

 

 

 

Note 1: This parameter is used to change the settings of other parameters. Therefore, ￿ is always displayed.

5

Note 2: ￿￿￿ cannot be set during the inverter operating. Always stop the inverter first and then program.

 

Note 3: When parameter ￿￿￿ is invoked, the value set previously is displayed on the left side of the parameter.

Note 4: If ￿￿￿ is set to ￿￿, the optional communication devices DEV002Z, PDP002Z and CCL001Z cannot be

 

used with the inverter. (The personal computer communications software PCM001Z cannot be used, either.) Furthermore, the copy function of the LED extended panel option (RKP002Z) does not work normally, so use only the parameter setting function and the monitoring function.

Note 5: If the power is turned off while the parameter ￿￿￿ is being set, an error (￿￿￿￿) will occur when the power is turned back on. If the ￿￿￿￿￿error occurs, set ￿￿￿ again.

[Programmed value]

50Hz default setting (￿￿￿=￿)

Setting ￿￿￿ at ￿ causes all the following parameters to be set for operation using a base frequency of 50Hz.

(This does not change the settings of any other parameters.)

• Maximum frequency ￿￿￿

: 50Hz

• VI/II input point 2 frequency ￿￿￿￿￿

: 50Hz

• Base frequency 1 ￿ ￿

: 50Hz

• RR/S4 input point 2 frequency ￿￿￿￿￿

: 50Hz

• Base frequency 2 ￿￿￿￿￿

: 50Hz

• RX input point 2 frequency ￿￿￿￿￿

: 50Hz

• Base frequency 3 ￿￿￿￿￿

: 50Hz

• AI1 input point 2 frequency ￿￿￿￿￿

: 50Hz

• Base frequency 4 ￿￿￿￿￿

: 50Hz

• AI2 input point 2 frequency ￿￿￿￿￿

: 50Hz

• Upper limit frequency ￿ ￿

: 50Hz

RP/high-speed pulse input point 2 frequency ￿￿￿￿￿

: 50Hz

• Forward speed limit input level ￿￿￿￿￿

: 50Hz

• PID deviation upper limit ￿￿￿￿￿

: 50Hz

• Reverse speed limit input level ￿￿￿￿￿

: 50Hz

• PID deviation lower limit ￿￿￿￿￿

: 50Hz

• Commercial power/inverter switching frequency ￿￿￿￿￿: 50Hz

• Process upper limit ￿￿￿￿￿

: 50Hz

• Point 2 frequency ￿￿￿￿￿

: 50Hz

• PID output upper limit ￿￿￿￿￿

: 50Hz

• Automatic light-load high-speed operation frequency ￿￿￿￿￿: 50Hz

• Motor rated rotational speed ￿￿￿￿￿ :1400~1480min-1 (According to model)

60Hz default setting (￿￿￿=￿)

Setting ￿￿￿ at ￿ causes all the following parameters to be set for operation using a base frequency of 60Hz.

(This does not change the settings of any other parameters.)

• Maximum frequency ￿￿￿

: 60Hz

• VI/II input point 2 frequency ￿￿￿￿￿

: 60Hz

• Base frequency 1 ￿ ￿

: 60Hz

• RR/S4 input point 2 frequency ￿￿￿￿￿

: 60Hz

• Base frequency 2 ￿￿￿￿￿

: 60Hz

• RX input point 2 frequency ￿￿￿￿￿

: 60Hz

• Base frequency 3 ￿￿￿￿￿

: 60Hz

• AI1 input point 2 frequency ￿￿￿￿￿

: 60Hz

• Base frequency 4 ￿￿￿￿￿

: 60Hz

• AI2 input point 2 frequency ￿￿￿￿￿

: 60Hz

• Upper limit frequency ￿ ￿

: 60Hz

RP/high-speed pulse input point 2 frequency ￿￿￿￿￿

: 60Hz

• Forward speed limit input level ￿￿￿￿￿

: 60Hz

• PID deviation upper limit ￿￿￿￿￿

: 60Hz

• Reverse speed limit input level ￿￿￿￿￿

: 60Hz

• PID deviation lower limit ￿￿￿￿￿

: 60Hz

• Commercial power/inverter switching frequency ￿￿￿￿￿: 60Hz

• Process upper limit ￿￿￿￿￿

: 60Hz

• Point 2 frequency ￿￿￿￿￿

: 60Hz

• PID output upper limit ￿￿￿￿￿

: 60Hz

• Automatic light-load high-speed operation frequency ￿￿￿￿￿: 60Hz

• Motor rated rotational speed ￿￿￿￿￿ :1680~1775min-1 (According to model)

E-42