E6581301

E-42

5
!
!
5.20 Standard default setting

V[R

V[RV[R

V[R : Factory default setting

Title Function Adjustment range Default setting
V[R Factory default
setting
: –
:50Hz default setting
:60Hz default setting
:Factory default setting
:Trip clear
:Cumulative operation time cleared
:Initialization of type information
:Save user-defined parameters
:Reset of user-defined parameters
:Cumulative fan operation time record clear
:Acceleration/deceleration time setting 0.01 sec.~600.0
sec. [Note 4]
:Acceleration/deceleration time setting 0.1 sec.~6000 sec.
Note 1: This parameter is used to change the settings of other parameters. Therefore, is always displayed.
Note 2: V[R cannot be set during the inverter operating. Always stop the inverter first and then program.
Note 3: When parameter V[R is invoked, the value set previously is displa yed on the left side of the parameter.
Note 4: If V[R is set to , the optional communication devices DEV002Z, PDP002Z and CCL001Z cannot be
used with the inverter. (The personal computer communications software PCM001Z canno t be used, either.)
Furthermore, the copy function of the LED extended panel option (RKP002Z) doe s not work normally, so use
only the parameter setting function and the monitoring function.
Note 5: If the power is turned off while the parameter V[R is being set, an erro r (GGR) will occur when the power
is turned back on. If the GGRerror occurs, set V[R again.
[Programmed value]

50Hz default setting (V[R

V[RV[R

V[R=

)

Setting V[R at causes all the following parameters to be set for operation usi ng a base frequency of 50Hz.
(This does not change the settings of any other parameters.)
• Maximum frequency HJ : 50Hz • VI/II input point 2 frequency CKH : 50Hz
• Base frequency 1 XN : 50Hz • RR/S4 input point 2 frequency CXH : 50Hz
• Base frequency 2 H : 50Hz • RX input point 2 frequency H : 50Hz
• Base frequency 3 H : 50Hz • AI1 input point 2 frequency H : 50Hz
• Base frequency 4 H : 50Hz • AI2 input point 2 frequency H : 50Hz
• Upper limit frequency WN : 50Hz
RP/high-speed pul se input poin t 2 frequency
H : 50Hz
• Forward speed limit input level H : 50Hz • PID deviation upper limit H : 50Hz
• Reverse speed limit input level H : 50Hz • PID deviation lower limit H : 50Hz
Commercial power/i nverter swit ching freque ncy
H: 50Hz • Process upper limit H : 50Hz
• Point 2 frequency H : 50Hz • PID output upper limit H : 50Hz
Automatic light-load high-speed operation frequency
H: 50Hz •
Motor rated rotational speed
H
:1400~1480min-1 (Ac cording to model )

60Hz default setting (V[R

V[RV[R

V[R=

)

Setting V[R at causes all the following parameters to be set for operation usi ng a base frequency of 60Hz.
(This does not change the settings of any other parameters.)
• Maximum frequency HJ : 60Hz • VI/II input point 2 frequency CKH : 60Hz
• Base frequency 1 XN : 60Hz • RR/S4 input point 2 frequency CXH : 60Hz
• Base frequency 2 H : 60Hz • RX input point 2 frequency H : 60Hz
• Base frequency 3 H : 60Hz • AI1 input point 2 frequency H : 60Hz
• Base frequency 4 H : 60Hz • AI2 input point 2 frequency H : 60Hz
• Upper limit frequency WN : 60Hz
RP/high-speed pul se input poin t 2 frequency
H : 60Hz
• Forward speed limit input level H : 60Hz • PID deviation upper limit H : 60Hz
• Reverse speed limit input level H : 60Hz • PID deviation lower limit H : 60Hz
Commercial power/inverter switching frequency
H: 60Hz • Process upper limit H : 60Hz
• Point 2 frequency H : 60Hz • PID output upper limit H : 60Hz
Automatic light-load high-speed operation frequency
H: 60Hz •
Motor rated rotational speed
H
:1680~1775min-1 (Ac cording to model )
• Function
This parameter is to set two or more parameters at a time for different command s. Using this parameter, all
parameters can be also return to their respective default settings by one op eration, and save or set specific
parameters individually.