E6581301

F-70

6
Ex.1:
H= (VI/II input), H= (disabled)

Output frequency = Reference frequenc y + Override (VI/II input [Hz])

Ex.2:
H= (VI/II input), H= (disabled)

Output frequency = Reference frequenc y + Override (VI/II input [Hz])

2) Multiplicative override
In this mode, each output frequency is multiplied by an externall y override frequency.
[Ex.1: RR/S4 (Reference frequency), VI/II (Override input)] [Ex.2 : RX (Reference frequency), VI/II (Overri de input)]
Output
frequency
0
10V
Over-ridden frequency
HJ
Output
frequency
0
10V
Over-ridden frequency
HJ
RR/S4
input
(Reference
frequency)
( )
RX input
(Reference
frequency)
( )
Reverse run
Forward run
Ex.1:
H= (Disabled), H= (VI/II input), HOQF=(RR/S4 input), HJ=, WN =
RR/S4 input, (H=, H=, H=, CXH=)
VI/II input (H=, H=, H=, H=)
Setting of RR/S4 input: Refer to Section 7.3.1, Setting of VI/II input: Refer to Section 7.3.2.

Output frequency = Reference frequenc y × {1 + Override (VI/II input [%]/100)}

Ex.2:
H= (Disabled), H= (VI/II input), HOQF= (RX input), HJ=, WN=
RX input (H=, H=, H=, H=)
VI/II input (H=, H=, H=, H=)
Setting of RX input: Refer to Section 7.3.3, Setting of VI/II input: Refer to Section 7.3.2.

Output frequency = Reference frequenc y × {1 + Override (VI/II input [%]/100)}

Ex.3:
Title Function Adjustment range Default setting
H Operation panel override multiplication gain ~% 

Outp ut frequency = Re ference freque ncy × {1 + Overri de (

H

HH

H

setting value [%]/100 }