!E6581301
C-5
3
4) Setting the frequency using input voltage (0~10Vdc)
[Parameter setting]
5) Setting the frequency using input voltage (0~±10Vdc)
The direction can be changed by switching between positi ve and negative signals.
[Parameter setting]
Set the “basic parameter frequency setting mode selection 1” parameter
HOQF

ҏ to

.

Note: Set reference frequency priority selection
H
to
(
HOQF
/
H
terminal switching, default setting).
Changing the settings of two speed command parameters at a ti me, refer to Section 6.6.
[Example of setting: To set the frequency by applying a current of 4(0)-20mAdc via the VI/II terminal.]
Key operated LED display Operation

Displays the operation frequency. (Perform during operation stopped.)
(When standard monitor display selection
H
=

[Output
frequency])
CWJ
Displays the first basic parameter “History function (
CWJ
).”
HOQF
Press either the or key to select “
HOQF
.”

Press the ENTER key to display the parameter setting (Default
setting:
).

Press the ke y to change the parameter to
.
HOQF
Press the ENTER key to save the changed parameter.
HOQF
and the
parameter are displayed alternately.
MODE
Frequency
0
0Vdc 10Vdc
60Hz

Set the “extended parameter analog input VI/II voltage/current switching”

parameter

HOQF

to

.

In addition, set the “basic parameter frequency setting mode selection 1” parameter

H

to

(

default setting

)

.

+
-
RX
CCA
-10Vdc
+10Vdc
Forward run
Reverse run
60Hz
60Hz
+
-
ENT
ENT
V
II
CCA
"
Voltage signal
Voltage signal (0~10V) for setting the operation frequency
Refer to Section 7.3 for details of adjustment.

:Voltage signal

0

-

10Vdc

"
Voltage signal
Voltage signal (0~±10V) for setting the operation frequency
Refer to Section 7.3 for details of adjustment.

:Voltage signal 0~±10Vdc