! E6581301 J-7
10
Selection table of separate-type options (1/2)
Voltage
class
Applicable
motor
[kW]
Inverter
model
EMC filter
(*1)
DC reactor
(DCL)
Dynamic
brake drive circuit
(GTR7)
(*2)
Control power
supply backup
200V
class
0.4 VFAS1-2004PL Built -in Option Built-in Option
0.75 VFAS1-2007PL Built -in Option Built-in Option
1.5 VFAS1-2015PL Built -in Option Built-in Option
2.2 VFAS1-2022PL Built -in Option Built-in Option
3.7/4.0 VFAS1-2037PL Built -in Option Built-in Option
5.5 VFAS1-2055PL Built -in Option Built-in Option
7.5 VFAS1-2075PL Built -in Option Built-in Option
11 VFAS1-2110PM Option Built-in Built-in Option
15 VFAS1-2150PM Option Built-in Built-in Option
18.5 VFAS1-2185PM Option Built-i n Built-in Option
22 VFAS1-2220PM Option Built-in Built-in Option
30 VFAS1-2300PM Option Built-in Built-in Option
37 VFAS1-2370PM Option Built-in Built-in Option
45 VFAS1-2450PM Option Built-in Built-in Option
55 VFAS1-2550P Option Attached as
standard Built-in Option
75 VFAS1-2750P Option Attached as
standard Built-in Option
400V
class
0.75 VFAS1-4007PL Built -in Option Built-in Option
1.5 VFAS1-4015PL Built -in Option Built-in Option
2.2 VFAS1-4022PL Built -in Option Built-in Option
3.7/4.0 VFAS1-4037PL Built -in Option Built-in Option
5.5 VFAS1-4055PL Built -in Option Built-in Option
7.5 VFAS1-4075PL Built -in Option Built-in Option
11 VFAS1-4110PL Built-in Option Built-in Option
15 VFAS1-4150PL Built-in Option Built-in Option
18.5 VFAS1-4185PL Built -in Built-in Built-in Option
22 VFAS1-4220PL Built-in Built-in Built-in Option
30 VFAS1-4300PL Built-in Built-in Built-in Option
37 VFAS1-4370PL Built-in Built-in Built-in Option
45 VFAS1-4450PL Built-in Built-in Built-in Option
55 VFAS1-4550PL Built-in Built-in Built-in Option
75 VFAS1-4750PL Built-in Built-in Built-in Option
90 VFAS1-4900PC Built-in Attached as
standard Built-in Option
110 VFAS1-4110KPC Built -in Attached as
standard Built-in Option
132 VFAS1-4132KPC Built -in Attached as
standard Built-in Option
160 VFAS1-4160KPC Built -in Attached as
standard Built-in Option
200 VFAS1-4200KPC Built -in Attached as
standard Option Option
220 VFAS1-4220KPC Built -in Attached as
standard Option Option
280 VFAS1-4280KPC Built -in Attached as
standard Option Option
355 VFAS1-4355KPC Built -in Attached as
standard Option Option
400 VFAS1-4400KPC Built -in Attached as
standard Option Option
500 VFAS1-4500KPC Built -in Attached as
standard Option Option
(*1):For the types and effects of EMC filters, ref er to section 9.1.
(*2):An optional braking resistor is required f or every model of any capacity (see Selection table of separate-type options (2/2)).