K-38

!

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensorless vector/vector with sensor (￿:Effective, -:Ineffective)

[30] My function [5/5]

 

 

 

 

 

 

 

Communi

 

 

 

 

Minimum

 

 

Vector control

 

 

 

Title

cation

Function

 

Adjustment range

setting unit

Default

Write during

Speed

Torque

PM

V/f Constant

Reference

 

(Panel/Communi

setting

running

control

 

No.

 

 

 

 

cation)

 

 

control

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:Disabled

 

 

 

 

 

 

 

 

 

 

 

 

1:VI/II

 

 

 

 

 

 

 

 

 

 

 

 

2:RR/S4

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0962

Analog input function target 21

3:RX

1/1

0

Enabled

*1

 

 

 

 

4:Optional AI1+, Optional AI1-

 

 

 

 

 

 

 

 

 

 

 

 

5:Optional AI2

 

 

 

 

 

 

 

 

 

 

 

 

6:Internal memory2

 

 

 

 

 

 

 

 

￿￿￿￿￿

0964

Analog function assigned object

0~10

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

*1

 

 

21

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0965

Monitor output function target 11

2000~2099:FD00~FD99

1/1

2000

Enabled

￿/￿

￿/￿

￿

￿

*1

 

 

 

 

3000~3099:FE00~FE99

 

 

 

 

 

 

 

 

￿￿￿￿￿

0966

Monitor output function

0:Normal monitor, 1:Max. value, 2:Min. value

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

*1

command 11

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0967

Monitor output function target

2000~2099:FD00~FD99

1/1

2000

Enabled

￿/￿

￿/￿

￿

￿

*1

21

 

3000~3099:FE00~FE99

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0968

Monitor output function

0:Normal monitor, 1:Max. value, 2:Min. value

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

*1

command 21

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0969

Monitor output function target

2000~2099:FD00~FD99

1/1

2000

Enabled

￿/￿

￿/￿

￿

￿

*1

31

 

3000~3099:FE00~FE99

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0970

Monitor output function

0:Normal monitor, 1:Max. value, 2:Min. value

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

*1

command 31

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0971

Monitor output function target

2000~2099:FD00~FD99

1/1

2000

Enabled

￿/￿

￿/￿

￿

￿

*1

41

 

3000~3099:FE00~FE99

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0972

Monitor output function

0:Normal monitor, 1:Max. value, 2:Min. value

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

*1

command 41

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0973

Virtual input terminal selection 1

0~155 *2

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

*1

￿￿￿￿￿

0974

Virtual input terminal selection 2

0~155 *2

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

*1

￿￿￿￿￿

0975

Virtual input terminal selection 3

0~155 *2

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

*1

￿￿￿￿￿

0976

Virtual input terminal selection 4

0~155 *2

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

*1

 

 

 

 

0:Disabled

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0977

My function selection

1:My function + permission signal

1/1

0

Disabled

*1

 

 

 

 

2:My function always ON

 

 

 

 

 

 

 

 

*1: ￿ For details, refer to Instruction Manual (E6581335) specified in Section 6.42. *2: ￿ For the adjustment range, see the table on page K-43.

[31] Travenirse function

 

 

 

Sensorless vector/vector with sensor (￿:Effective, -:Ineffective)

 

Communi

 

 

Minimum

 

 

Vector control

 

 

 

Title

cation

Function

Adjustment range

setting unit

Default

Write during

Speed

Torque

PM

V/f Constant

Reference

(Panel/Communi

setting

running

control

 

No.

 

 

cation)

 

 

control

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0980

Traverse selection

0:Disabled

1/1

0

Disabled

￿/￿

-

￿

￿

*1

1:Enabled

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0981

Traverse acceleration time

0.1~120.0 sec.

0.1/0.1

25.0

Enabled

￿/￿

-

￿

￿

*1

￿￿￿￿￿

0982

Traverse deceleration time

0.1~120.0 sec.

0.1/0.1

25.0

Enabled

￿/￿

-

￿

￿

*1

￿￿￿￿￿

0983

Traverse step

0.0~25.0%

0.1/0.1

10.0

Enabled

￿/￿

-

￿

￿

*1

￿￿￿￿￿

0984

Traverse jump step

0.0~50.0%

0.1/0.1

10.0

Enabled

￿/￿

-

￿

￿

*1

*1: ￿ For details, refer to Instruction Manual (E6581337) specified in Section 6.42.

!

!

E6581301!