5.13 Selecting forward and reverse runs (operation panel only)

HT

HTHT

HT : Forward/reverse run selection

[Parameter setting]
Title Function Adjustment range Default setting
HT Forward/reverse run selection
: Forward run
: Reverse run
: Forward run (F/R switching possible)
: Reverse run (F/R switching possible)
!Check the direction of rotation on the status monitor.
HTH: Forward run HTT: Reverse run
For monitoring, refer to Section 8.1.
!When the F and R terminals are used for switching between forward run an d stop from the terminal board, the HT
forward/reverse run selection parameter is rendered invalid.
Short across the F-CC terminals: forward run
Short across the R-CC terminals: reverse run
!If F and CC, as well as R and CC are connected at the same time: Stop (Default setting)
Use the parameter H to select between reverse run and stop in this case.
For more details, refer to Section 6.2.1.
!This function is valid only when EOQF is set at (Operation panel input enabl ed).
! To switch between forward run and reverse run from the control panel with parameter HT set to or , perfo rm
these steps: to switch to forward run, press the key while holding the key down, or to swit ch to
reverse run, press the key while hol ding key down.
• Function
Program the direction of rotation of the motor when the running and stopping a re made using the RUN key and
STOP key on the operation panel.
Valid when EOQF (command mode selection) = (operation panel input).