! E6581301!

H-5

8
8.2.2 Display of detailed information on a past trip
Details on a past trip (of trips 1 to 4) can be displayed, as s hown in the table below, by pressing the key when the
trip record is selected in the status monitor mode.
Unlike the " Monitor display at tripping " in 8.4.2, detail s on a past trip can be displayed, even a fter the inverter is turned
off or reset.
Item displayed

Key

operated

LED display Description
Past trip 1 QE
Past trip 1 (displayed alternately.)
Continuous trips P The number of time the same trip occurred in succes sion is displayed.
(QEC, QEC, QEC, QEN Unit: times)
Output frequency  The operation frequency when the trip occurred is di splayed.
Status monitor mode
(Rotating direction) HTH The direction of rotation is displayed. (H:Forward run, T:Reverse run)
Frequency command
value  The operation frequency command value is displayed.
(When H=, Frequency command)
Output current E The inverter output current (load current) is displ ayed.
(When H=, Output current)
Input voltage (DC
detection) [ The inverter DC voltage is displayed. (Default setting unit: %)
(When H=, Input voltage) [Note 3]
Output voltage R The inverter output voltage i s displayed. (Default setting unit: %)
(When H=, output voltage)
Input terminal
information KKKKKKKK
The ON/OFF status of each of the control signal input te rminals (F, R,
ST, RES, S1, S2, S3, RR/S4) is displayed in bits.
Output terminal
information The ON/OFF status of each of the control signal output terminals
(OUT1, OUT2, FL) is displayed in bits.
Cumulative operation
time V The cumulative operation time when the trip occurred is displayed.
(0.01=1 hour, 1.00=100 hours)
Past trip 1 QE
Press this key to return to past trip 1.
Note 1: Press the or key to change i tems displayed in the status monitor mo de.
Note 2: You can switch between % and A (ampere)/V (volt), using the parameter FURW (c urrent/voltage unit
selection).
Note 3: The input voltage displayed is 1/
2
times as large as the rectified DC input voltage.
Note 4: The number of bars displayed varies depending on the setting of H (logic output/pul se train output
selection). The bar representing the OUT1 terminal is disp layed only when logic output functio n is assigned to it.
If H= :The bar representing OUT1 is display ed.
If H= :The bar representing OUT1 is not displ ayed.
Note 5: If there is no trip record, PGTT is displayed.
Note 6: The cumulative operation time increments only when the machine is in operation.
ENT
ENT
[Note 5]
[Note 1]
MODE
[Note 6]
[Note 4]
[Note 2]
[Note 2]
[Note 3]
[Note 2]