E6581301

Frequency [Hz]

 

Operation frequency

 

If the torque limit function

 

 

 

 

 

 

 

 

 

 

 

is not activated

 

 

Actual speed

Time [s]

Torque [N·m] Torque limit level

ON

Mechanical brake

OFF

Time [s]

(released)

Time [s]

(2)￿￿￿￿=￿(In sync with min. time)

The operation frequency keeps increasing, even if the torque limit function is activated.

In this control mode, the actual speed is kept in sync with the operation frequency, while torque is held at a limit level when it decreases as a result of the release of the mechanical brake. The use of this function prevents the load from failing and improves the motor’s response during inching operation.

6

Frequency [Hz]

 

Operation frequency

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Actual speed

 

 

 

 

 

 

 

 

 

 

(Acceleration rates vary depending

 

 

 

 

 

 

 

 

 

 

on the torque limit level.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time [s]

Torque [N·m]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Torque is held at a limit level even

 

 

 

 

 

 

 

Torque limit level

 

 

 

 

 

 

after the mechanical brake is released.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

Time [s]

 

 

 

 

 

 

 

 

Mechanical brake

 

 

 

 

OFF

 

 

 

 

(released)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Time [s]

F-48