K-28

!

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensorless vector/vector with sensor (￿:Effective, -:Ineffective)

[28] Operation panel parameters [2/3]

 

 

 

 

 

Communi

 

 

 

 

Minimum

 

 

Vector control

 

 

 

Title

cation

Function

 

Adjustment range

setting unit

Default

Write during

Speed

Torque

PM

V/f Constant

Reference

 

(Panel/Communi

setting

running

control

 

No.

 

 

 

 

cation)

 

 

control

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0725

Operation panel torque

-250~250%

1/0.01

0

Enabled

-

￿/￿

-

-

6. 36. 7

command

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0727

Operation panel tension torque

-250~250%

1/0.01

0

Enabled

-

￿/￿

-

-

6. 36. 8

bias

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0728

Operation panel load sharing

0~250%

1/0.01

100

Enabled

-

￿/￿

-

-

6. 36. 8

gain

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0729

Operation panel override

-100~100%

1/0.01

0

Enabled

￿/￿

-

￿

￿

6. 34

multiplication gain

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0730

Operation panel frequency

0:Permit

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 1

setting prohibition selection

1:Prohibit

 

 

 

 

 

 

 

 

 

 

 

 

LED/LCD panel cable breakage

0$Disconnection detection (￿￿￿￿ trip)

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0731

1$No disconnection detection (retain operation

1/1

1

Enabled

6.33.26

 

 

detection selection

command)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Operation panel emergency

0:Permit

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0734

stop operation prohibition

1/1

0

Enabled

6. 36. 1

1:Prohibit

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0735

Operation panel reset operation

0:Permit

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 1

prohibition selection

1:Prohibit

 

 

 

 

 

 

 

 

 

 

 

 

Prohibition of change of

0:Permit

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0736

￿￿￿￿/￿￿￿￿ during

1/1

1

Enabled

6. 36. 1

1:Prohibit

 

 

operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0737

All key operation prohibition

0:Permit

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 1

1:Prohibit

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0740

Trace selection

0:Deselect, 1:At tripping, 2:At triggering

1/1

1

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0741

Trace cycle

0:4ms, 1:20ms, 2:100ms, 3:1s, 4:10s

1/1

2

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0742

Trace data 1

0~49

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0743

Trace data 2

0~49

1/1

1

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0744

Trace data 3

0~49

1/1

2

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0745

Trace data 4

0~49

1/1

3

Enabled

￿/￿

￿/￿

￿

￿

6. 37

￿￿￿￿￿

0748

Integrating wattmeter retention

0:Disabled

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 38

selection

1:Enabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:1=1kWh

 

 

 

 

 

 

 

 

 

 

Integrating wattmeter display

1:1=10kWh

 

 

 

 

 

 

 

 

￿￿￿￿￿

0749

2:1=100kWh

1/1

*2

Enabled

￿/￿

￿/￿

￿

￿

6. 38

unit selection

 

 

3:1=1000kWh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4:1=10000kWh

 

 

 

 

 

 

 

 

 

 

 

 

0:Quick mode/standard setting mode switching

 

 

 

 

 

 

 

 

 

 

 

 

function

 

 

 

 

 

 

 

 

 

 

 

 

1:Shortcut key:Pressing for 2 sec. to record the

 

 

 

 

 

 

 

 

 

 

 

 

 

parameter, pressing normally to jump

 

 

 

￿/￿

￿/￿

￿

￿

 

￿￿￿￿￿

0750

EASY key function selection

 

to recorded parameter (first jump to

1/1

0

Disabled

5. 22

 

 

 

 

 

the 1st history)

 

 

 

 

 

 

 

 

 

 

 

 

2:Operation panel/remote key:Operation panel by

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

 

 

3:Monitor peak minimum hold trigger

 

 

 

 

 

 

 

 

*1: The communication number of the parameter is used for this setting.

*2: Default values vary depending on the capacity. ￿ See the table of K-48.

!

!

E6581301!

Page 282
Image 282