E6581301!

 

 

 

3) Connection with transistor output

￿ Inverter

Input terminal

CC

Programmable controller

!The inverter can be controlled by connecting the input terminal with output (contactless switch) of a programmable controller. Use this function to specify forward/reverse run or a preset speed operation. Use a transistor that operates on 24Vdc, 5mA power.

* Interface between programmable controller and inverter

When using an open-collector output type programmable control device to control the operation of a motor, connect cables, as shown in the schematic diagram for sink/source logic (when an external power supply is used) on page B-15. When using the internal power supply of the inverter, connect cables, as shown in the schematic diagram on page B-14. If the programmable control device is turned off with the inverter left on, an incorrect signal will flow into the inverter, as shown in the figure below, because there is a potential difference between the control power supplies. Be sure to provide an interlock so that the programmable controller cannot be turned off when the inverter is on.

￿

Programmable controller

 

 

Inverter

 

 

 

 

+24V

 

Fuse blowout

 

External +24V

 

 

 

P24

power supply

 

 

 

detector circuit

Input terminal

 

 

 

 

Inverter internal

7

 

 

 

 

 

 

(F, R, ST….)

 

 

 

+24V power

 

 

 

 

 

COM

 

 

supply

 

 

Fuse

 

 

 

 

Example of use- three-wire operation (SW1 set to sink logic)

The three-wire operation function allows you to make the inverter self-hold its operation, without setting up a sequential circuit, so that the inverter can be operated by means of external signals (reset contact signals).

￿

F

R

S3

CC

Forward run

Forward run (F): If you press the Forward (F) button, the

motor rotates in the forward direction at the

 

 

frequency specified with a command.

Reverse run

Reverse run (R): If you press the Reverse (R) button, the

 

motor rotates in the reverse direction at the

HD

frequency specified with a command.

 

HD (S3): If you press the HD (S3) button, the motor

 

decelerates and comes to a stop.

[Parameter setting]

Terminal

Title

Function

Adjustment range

Example of setting

symbol

 

 

 

 

S3

￿￿￿￿￿

Input terminal function

￿"￿￿￿

￿￿￿

selection 7(S3)

( HD operation retention)

G-3

Page 208