E6581301

F-5

6
•Function
These parameters are used to switch signals to be sent to the analog input terminals VI/II and AI2 (optional).
ST-CC
"3-CC
(Jog run)!
Output frequency [Hz]!
Forward run!
Forward run !
#
Set frequency
Panel key!
RUN
STOP
RUN
STOP
RUN
STOP
6.2.3 Analog input signal switchingHHHH : Analog input VI/II voltage/current switching HHHH : Analog input AI2 (optional circuit board) voltage/current switching
[Parameter setting]
Title Function Adjustment range Example of setting
H Analog VI/II voltage/current switching : Voltage input
: Current input 
H Analog input AI2 (optional circuit board)
voltage/current switching
: Voltage input
: Current input 
When using the analog input terminal VI/II
as a voltage input terminal (VI)
H=
When using the analog input terminal VI/II
as a voltage input terminal (II)
H=

CCA VI/II

0~10V input

CCA VI/II

0~20mA(4~20mA) input

CCA: Analog

common

For an explanation of input gain and bias adjustments, refer to Secti on 6.28.