K-39
E6581301
!
11
[Contents of monitor displays] Sensorless vector/vector with sensor (Ɣ: valid, -: invalid)
Communi
cation No.
Function
Unit
(Commun
ication)
Monitor output
selection
Trip
retention
Meter
output
selection
Speed
control
Torque
control PM control V/f Reference
- Standard monitor - H * 1
8.2.1
Contents of status monitor display
FE31 Pattern operation group selection - at a pattern
operation ż - Ɣ/Ɣ - Ɣ Ɣ
FE32 Number of times to repeat current
pattern 1 at a pattern
operation ż - Ɣ/Ɣ - Ɣ Ɣ
FE33 Pattern operation - number of preset
speeds 1 at a pattern
operation ż - Ɣ/Ɣ - Ɣ Ɣ
FE34 Remaining time of current pattern
operation 1 at a pattern
operation ż - Ɣ/Ɣ - Ɣ Ɣ
FE01 Status (rotation direction) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Status monitor 1 - H * 1
- Status monitor 2 - H * 1
- Status monitor 3 - H * 1
- Status monitor 4 - H * 1
- Status monitor 5 - H * 1
- Status monitor 6 - H * 1
- Status monitor 7 - H * 1
- Status monitor 8 - H * 1
FE00 Output frequency monitor 0.01Hz
when tripped when tripped
- Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE06 Input terminal information - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Input terminal i nformation (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Input terminal i nformation (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE07 Output terminal information - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
- Output terminal i nformation (optional) - Fixed ż - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE08 CPU1 version 1 Fi xed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE73 CPU2 version - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE10 Past trip 1 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE11 Past trip 2 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE12 Past trip 3 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE13 Past trip 4 - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE79 Part replacement alarm information - Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
FE14 Cumulative operation time 1h Fixed × - Ɣ/Ɣ Ɣ/Ɣ Ɣ Ɣ
*1: Status in a trip may not be held depending on selected function. Refer to next page; [Monitor FM/AM/pul se output function selection].