E6581301!

 

(Continued)

 

 

 

 

 

 

 

 

 

Item

Specification

 

 

 

 

 

 

Alarms

Stall prevention during operation, overload limit, overload, undervoltage on power source side, DC circuit

 

 

 

 

 

 

undervoltage, setting error, in retry, upper limit, lower limit.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Overcurrent, overvoltage, overheat, short circuit on the load side, ground fault on the load side, inverter

 

 

 

 

 

 

 

overload, arm overcurrent at starting, overcurrent on the load side at starting, CPU error, EEPROM error,

 

 

 

 

 

 

Causes of

RAM error, ROM error, communication error, (dynamic braking resistor overcurrent/overload),

 

 

 

 

 

 

failures

(emergency stop), (undervoltage), (low current), (overtorque), (motor overload), (input phase failure),

 

 

 

 

 

 

 

(output phase failure)

 

 

 

 

 

 

 

The items in the parentheses are selectable.

 

 

Display

 

 

 

 

Operation frequency, operation frequency command, forward run/reverse run, output current, DC

 

 

4-digit

 

 

voltage, output voltage, compensated frequency, terminal board input/output information, CPU version,

 

 

 

 

and

 

 

past trip history, cumulative operation time, speed feedback, torque, torque command, torque current,

 

 

function

7-segme

 

Monitoring

exiting current, PID feedback value, motor overload factor, inverter overload factor, PBR overload factor,

 

 

nt LED

 

function

PBR load factor, input power, output power, peak output current, peak DC voltage, RR/S4 input, VI/II

 

 

 

 

 

 

 

 

input, RX input, AI1 input, AI2 input, FM output, AM output, expansion I/O card option CPU version,

 

 

 

 

 

 

 

integral input power, integral output power, communication option reception counter, communication

 

 

 

 

 

 

 

option abnormal counter

 

 

 

 

 

 

Free unit display

Display of optional units other than output frequency (motor speed, line speed, etc), current ampere/%

 

 

 

 

 

 

switch, voltage volt/% switch

 

 

 

 

 

 

Automatic edit

Searches automatically parameters that are different from the standard default setting parameters. Easy

 

 

 

 

 

 

function

to find changed parameters.

 

 

 

 

 

 

User default

User parameter settings can be saved as default settings. Allows to reset the parameters to the

 

 

 

 

 

 

setting

user-defined parameter settings.

 

 

 

LED

 

Charge display

Displays main circuit capacitor charging.

 

 

Input/output terminal input

Possible to select positive logic or negative logic with programmable input/output terminal function menu.

 

 

[Note 1] [Note 2]

 

 

 

function

 

 

 

 

 

 

(Default setting: positive logic)

 

 

 

 

 

 

 

 

 

 

Sink/source switching

Possible to switch between minus common (CC) and plus common (P24) for control terminal.

 

 

(Default setting: minus common (CC))

 

 

 

 

 

 

 

 

 

 

 

 

Failure detection signal

1c contact output (250Vac-2A-cos￿=1, 250Vac-1A-cos￿=0.4, 30Vdc-1A)

 

 

 

 

Low speed/speed reach

 

 

 

 

 

 

signal output

Open collector output (24Vdc, max. 50mA, output impedance: 33￿)

 

 

 

 

[Note 2]

 

 

 

 

 

 

output

 

Upper/lower limit

 

 

 

 

 

frequency signal output

Open collector output (24Vdc, max. 50mA, output impedance: 33￿)

 

 

 

 

 

 

 

signal

 

[Note 2]

 

 

 

 

 

 

 

Output for frequency

 

 

 

 

 

 

 

 

 

 

 

 

meter/

 

 

Analog output. 1mAdc full-scale DC ammeter or 7.5Vdc-1mA voltmeter

 

 

 

 

 

Output for ammeter

 

 

 

 

 

 

 

 

 

 

[Note 3]

 

 

 

 

 

 

 

 

Pulse train frequency

Open collector output (24Vdc, max. 50mA)

 

 

 

 

output

 

 

 

 

 

 

Communication function

RS-485 standard 2-channel equipped (connector: modular 8P)

 

 

CC-Link, DeviceNet and PROFIBUS-DP are optional.

 

 

 

 

 

 

 

 

 

 

Environments

 

Use environments

Indoor use. Altitude: 3000m or less (current reduction necessary if 1000m or more.) Place not exposed

 

 

 

 

 

 

to direct sunlight and free of corrosive and explosive gases.

 

 

 

 

 

 

 

 

 

 

 

 

Ambient temperature

-10 to +60°C (Remove the upper c over if 40°C or more, max. 60°C) [Note 4]

 

 

 

 

Storage temperature

-25 to +70°C

 

 

 

 

Relative humidity

20 to 93% (free from condensation)

 

 

 

 

Vibration

5.9m/s2{0.6G} or less (10 to 55Hz) (Compliant with JIS C60068-2-6)

 

Note 1: 16 contact input terminals (of which 8 are options) are programmable contact input terminals, and they make it possible to arbitrarily select from 114 types of signals.

Note 2: Programmable ON/OFF output terminals make it possible to arbitrarily select from 168 types of signals.

Note 3: Programmable analog output terminals make it possible to arbitrarily select from 54 types of signals.

Note 4: When using inverters where the ambient temperature will rise above 50°C, remove the upper cove r and operate each inverter at a current lower than the rated one.

12 (200V-55kW or lager and 400V-90kW or larger models dose not need remove the upper cover) Note 5: This function protects inverters from overcurrent due to output circuit ground fault.

L-4

Page 306
Image 306
Toshiba VF-AS1 instruction manual Led