7.Operation with external signal

7.1External operation

The inverter can be freely controlled externally.

Parameters must be differently set depending on the operation method. Make sure of the operation method before setting parameters, and set parameters properly to the operation mode according to the procedure mentioned below.

[Steps in setting parameters]

￿

Check of external signal conditions

 

Operation signal: operation panel Speed command: operation panel

Refer to Section 5.5 Example 1.

Operation signal: terminal board Speed command: operation panel

Refer to Section 5.5 Example 2.

Operation signal: operation panel Speed command: terminal board

Refer to Section 5.5 Example 3.

Operation signal: terminal board Speed command: terminal board

Refer to Section 5.5 Example 4.

In case of control panel operation command input

￿￿￿￿=￿ (Operation panel input enabled)

In case of control panel operation the frequency

￿￿￿￿=￿ (Operation panel input enabled)

In case of run/stop with external input

￿￿￿￿=￿ (Terminal input enabled) *

￿(2-wire RS485 communication input)

￿(4-wire RS485 communication input)

￿(Communication option input)

*Sink logic and source logic (logic of input/output terminal) are switchable to each other.

For details, refer to Section 2.3.2.

In case of set the frequency with external input

￿￿￿￿=￿ (VI/II (voltage/current input))

￿(RR/S4 (potentiometer/voltage input))

￿(RX (voltage input))

￿(2-wire RS485 communication input)

￿(4-wire RS485 communication input)

￿(Communication option input)

￿(Optional AI1 (Differential current input))

￿(Optional AI2 (voltage/current input))

￿￿(Motor operated pot mop setting)

￿￿(RP pulse input)

￿￿(High speed pulse input)

￿￿- (Unsupported)