E6581301

!The functions assigned to the following control input terminals (contact input: ￿ Refer to Section 7.2) are always activated regardless of the settings of the command mode selection ￿￿￿￿ and frequency setting mode selection

1￿￿￿￿.

Reset terminal (default setting: RES, valid only for tripping)

Standby terminal (assigned to ST by default)

Emergency stop terminal

!To make changes in the command mode selection ￿￿￿￿ and the frequency setting mode selection 1 ￿￿￿￿

first stop the inverter temporarily.

No change can be made to them if the inverter is in operation.

Preset speed operation

￿￿￿￿: Set this parameter at ￿ (terminal board).

￿￿￿￿: Any setting is valid.

1) Setting the run, stop and operation frequencies with the operation panel

Title

Function

Example of setting

￿￿￿￿

Command mode selection

￿ (Operation

panel input)

 

 

￿￿￿￿

Frequency setting mode

￿ (Operation

selection 1

panel input)

 

5

Run/stop :Press the RUN and STOP keys

on the operation panel

!To switch between forward run and reverse run, use the forward/reverse run selection ￿￿.

Speed command :Press the

and

keys on the operation

panel to set the frequency.

 

 

 

 

Motor

Power

R/L1

 

U/T1

IM

supply

S/L2

 

V/T2

T/L3

 

W/T3

 

 

 

 

 

 

F

 

 

 

Inverter

 

 

 

 

R

 

 

 

 

ST

Shorted by a shorting bar when

 

 

 

CC

shipped from the factory.

 

 

 

 

 

CCA

RX

VI/II RR/S4 PP

(-H1,HN,WN products.)

 

 

To save the frequency, press the ENTER key. Then, ￿￿ and the set frequency are displayed alternately for a while.

E-8

Page 78
Image 78
Toshiba VF-AS1 instruction manual Preset speed operation, Set this parameter at terminal board Any setting is valid