K-40

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[Monitor FM/AM/pulse output function selection (1/3)]

 

 

 

Sensorless vector/vector with sensor ￿: valid, -: invalid)

FM/AM/pulse output

Monitor output

 

 

 

Unit

 

Speed

 

Torque

 

 

 

 

 

 

 

 

 

Function

(Communicat

Trip retention

 

PM control

V/f

Reference

Option No.

Communicati

Option No.

Communicati

 

 

control

 

control

 

 

 

ion)

 

 

 

 

 

on No.

on No.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

FD00

0

FE00

Output frequency

0.01Hz

￿

￿/￿

 

￿/￿

￿

￿

 

1

FD02

1

FE02

Frequency command value

0.01Hz

￿

￿/￿

 

-

￿

￿

 

2

FD03

2

FE03

Output current

0.01%

￿

￿/￿

 

￿/￿

￿

￿

 

3

FD04

3

FE04

Input voltage (DC detection)

0.01%

￿

￿/￿

 

￿/￿

￿

￿

 

4

FD05

4

FE05

Output voltage

0.01%

￿

￿/￿

 

￿/￿

￿

￿

 

5

FD15

5

FE15

Compensated frequency

0.01Hz

￿

￿/￿

 

￿/￿

￿

￿

 

6

FD16

6

FE16

Speed feedback (real-time value) *1

0.01Hz

￿

-/￿

 

-/￿

-

-

 

7

FD17

7

FE17

Speed feedback (1-second filter) *1

0.01Hz

￿

-/￿

 

-/￿

-

-

 

8

FD18

8

FE18

Torque

0.01%

￿

￿/￿

 

￿/￿

￿

￿*2

 

9

FD19

9

FE19

Torque command

0.01%

￿

-

 

￿/￿

-

-

 

11

FD20

11

FE20

Torque current

0.01%

￿

￿/￿

 

￿/￿

-

￿*2

 

12

FD21

12

FE21

Exciting current

0.01%

￿

￿/￿

 

￿/￿

-

￿*2

 

13

FD22

13

FE22

PID feedback value

0.01Hz

￿

￿/￿

 

-

￿

￿

 

14

FD23

14

FE23

Motor overload factor (OL2 data)

0.01%

￿

￿/￿

 

￿/￿

￿

￿

 

15

FD24

15

FE24

Inverter overload factor (OL1 data)

0.01%

￿

￿/￿

 

￿/￿

￿

￿

 

16

FD25

16

FE25

Regenerative braking resistance

1%

￿

￿/￿

 

￿/￿

￿

￿

 

overload factor (OLr data)

 

 

 

 

 

 

 

 

 

 

 

 

 

5.16

17

FD28

17

FE28

Regenerative braking resistor load factor (% ED)

1%

￿

￿/￿

 

￿/￿

￿

￿

 

8.3

18

FD29

18

FE29

Input power

0.01kW

￿

￿/￿

 

￿/￿

￿

￿

 

 

19

FD30

19

FE30

Output power

0.01kW

￿

￿/￿

 

￿/￿

￿

￿

 

23

FE39

23

FE39

Optional AI2 input

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

24

FE35

24

FE35

RR/S4 input

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

25

FE36

25

FE36

VI/II input

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

26

FE37

26

FE37

RX input

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

27

FE38

27

FE38

Optional AI1 input

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

28

FE40

28

FE40

FM output

0.01

×

￿/￿

 

￿/￿

￿

￿

 

29

FE41

29

FE41

AM output

0.01

×

￿/￿

 

￿/￿

￿

￿

 

30

FE51

-

-

Fixed output 1

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

31

FA51 *3

-

-

Communication data output

1

×

￿/￿

 

￿/￿

￿

￿

 

32

FE50

-

-

Fixed output 2

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

33

FE52

-

-

Fixed output 3

0.01%

×

￿/￿

 

￿/￿

￿

￿

 

-

-

32

FE66

Attached to expansion I/O card 1 CPU

-

×

￿/￿

 

￿/￿

￿

￿

 

version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-

-

33

FE67

Attached to expansion I/O card 2 CPU

-

×

￿/￿

 

￿/￿

￿

￿

 

version

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*1: Estimated speed is output if there is no PG feedback. If used as pulse input command with PG feedback option, frequency is displayed as in the PG feedback.

 

 

*2: Reference data

 

 

 

 

 

 

 

 

 

 

 

 

 

*3: Communication no. FA51 is used for FM, FA52 for AM, FA53 for MON1 and FA54 for MON2 and pulse output, respectively.

 

 

 

 

 

￿For details, refer to Section 5.16; [Terminal FM-related parameters].

￿For monitor indications, refer to Section 8.3; [Set up values of monitor indication parameters].

E6581301!

Page 294
Image 294
Toshiba VF-AS1 instruction manual Control Ion