E6581301

10.5Optional internal devices

Here are the internal devices optionally available. There are two types of optional devices: Add-on type and Plug-in

type.

Table of optional devices

 

 

 

 

Option name

Function, purpose

Model

Type of

 

 

 

 

installation

 

 

 

 

 

 

 

Expansion

 

 

(1)

Expansion I/O card1 option

 

ETB003Z

Add-on

terminal

function

 

(Logic input/output + PTC input)

 

 

Used to extend input and output

 

 

(2)

Expansion I/O card2 option

 

 

terminals.

 

 

 

(Function of the above optional card 1

ETB004Z

Add-on

 

 

 

 

 

 

+ Analogue input/output + Pulse input)

 

 

 

Communication

 

 

(3)

CC-Link communication option

Used to connect to a CC-Link

CCL001Z

Add-on

 

 

network for control.

function

 

 

 

 

 

 

(4)

DeviceNet communication option

Used to connect to a DeviceNet

DEV002Z

Add-on

 

network for control.

 

 

 

 

 

 

(5) PROFIBUS-DP communication option

Used to connect to a

PDP002Z

Add-on

 

PROFIBUS-DP network for control.

 

 

 

 

 

 

 

 

 

 

(6)

PG feedback option

 

VEC004Z

Plug-in

 

 

 

 

(Push-pull 12V)

 

 

function

 

 

 

 

 

 

 

(7)

PG feedback option

Used to issue motor pulse train rate

VEC005Z

Plug-in

 

 

 

(Push-pull 15V)

 

 

 

commands or used for sensor

 

 

 

 

 

 

 

 

 

Other

 

(8)

PG feedback option

 

 

 

 

vector control.

VEC006Z

Plug-in

 

 

 

(Push-pull 24V)

 

 

 

 

 

 

 

 

 

(9)

PG feedback option

 

VEC007Z

Plug-in

 

 

 

 

(RS422-5V)

 

 

 

 

 

 

 

 

Functions of Add-on type options

(1)Expansion I/O card1 option (Logic input/output + PTC input)

Function

Description

 

 

 

Multifunction programmable contact

No-voltage contact input (24Vdc-5mA or less)

 

 

 

input (4 points)

Sink logic input (at a common voltage of 24V)

Source logic input

 

 

 

! ON: Less than 10Vdc

! ON: 11Vdc or more

 

 

 

! OFF: 16Vdc or more

! OFF: Less than 5Vdc

 

 

 

10

Multifunction programmable open

Driving current: Max. 50mA when an external power source is used

 

 

 

collector output (2 points)

Max. 20mA when the internal power source is used

 

 

 

Driving voltage: 12V (min) to 30V (max)

 

 

 

Multifunction programmable relay

1C contact configuration

 

 

 

contact output

250Vac-2A (cosφ=1), 250Vac-1A (cosφ=0.4), 30Vdc-1A

 

 

External thermal trip input

Resistance between TH+ and TH-

 

 

 

 

Error: Approx. 70￿ or less or approx. 3k￿ or more

 

 

 

Recovery from error: Approx. 1.6k￿

 

 

 

24V power output

24Vdc - 60mA max

 

 

 

-10V power output

-10Vdc -10mA

 

 

 

Contact input common terminal

Common terminals for contact input

 

 

 

J-9

Page 249
Image 249
Toshiba VF-AS1 instruction manual Table of optional devices, Functions of Add-on type options