Sink logic/source logic

Switching between sink logic and source logic (input/output terminal logic) is possible.

￿For details, refer to the Section 2.3.2.

7.2.2Functions of output terminals (incase of sink logic)

Use the above parameters to send various signals from the inverter to external equipment.

By setting parameters for the OUT1, OUT2 and FL (FLA, FLB and FLC) terminals on the terminal board, you can use 0~255 functions and functions obtained by combining them.

[Control terminal board]

How to use

￿

Function of OUT1··········To be set by parameter ￿￿￿￿

Function of OUT2··········To be set by parameter ￿￿￿￿

Functions of FLA, FLB, and FLC··········To be set by parameter ￿￿￿￿

 

FLA

 

 

FLB

 

 

FLC

7

 

P24

 

 

Ry

OUT1

 

Ry

OUT2

 

 

NO

 

 

CC

 

Setting of output terminal function

Terminal

Title

Function

Adjustment range

Default setting

symbol

 

 

 

 

OUT1

￿￿￿￿￿

Output terminal function

￿~￿￿￿

￿￿

selection 1

(Low-speed signal)

 

 

 

 

 

Output terminal function

 

￿￿

OUT2

￿￿￿￿￿

selection 2

￿~￿￿￿

(Acceleration/decele

 

 

 

 

ration completion)

FL

￿￿￿￿￿

Output terminal selection 3

￿~￿￿￿

￿￿￿

 

(Failure FL)

 

 

 

 

OUT3~OUT6

￿￿￿￿~ ￿￿￿￿

Output terminal function

￿~￿￿￿

￿￿￿￿

R1~R2

selection 4~9

 

 

 

R3, R4

￿￿￿￿, ￿￿￿￿￿

Output terminal function

￿~￿￿￿

￿￿￿￿

selection 10~11

 

 

 

 

Note1: ￿￿￿￿~￿￿￿￿ is for use of expansion terminal board 1 option unit.

Note2: ￿￿￿￿~￿￿￿￿ is for use of expansion terminal board 2 option unit.

Note3: ￿￿￿￿, ￿￿￿￿ is not supported (for options).

Note4: When use OUT1 terminal for pulse output function, refer to Section 6.35.1.