[Setup values of ￿￿￿￿~￿￿￿￿]

 

 

 

 

 

 

Default setting

Communication

Trace (monitor) function

Communication

 

 

 

 

No.

unit at tracing

 

 

 

 

 

 

 

 

 

 

￿￿

FD00

Output frequency

0.01Hz

 

 

 

 

￿￿

FD02

Frequency command value

0.01Hz

 

 

 

 

￿￿

FD03

Output current

0.01%

 

 

 

 

￿￿

FD04

Input voltage (DC detection)

0.01%

 

 

 

 

￿￿

FD05

Output voltage

0.01%

 

 

 

 

￿￿

FD15

Compensated frequency

0.01Hz

 

 

 

 

￿￿

FD16

Speed feedback (real-time value)

0.01Hz

 

 

 

 

￿￿

FD17

Speed feedback (1-second filter)

0.01Hz

 

 

 

 

￿￿

FD18

Torque

0.01%

 

 

 

 

￿￿

FD19

Torque command

0.01%

 

 

 

 

￿￿￿

FD20

Torque current

0.01%

 

 

 

 

￿￿￿

FD21

Exciting current

0.01%

 

 

 

 

￿￿￿

FD22

PID feedback value

0.01

 

 

 

 

￿￿￿

FD23

Motor overload factor (OL2 data)

0.01%

 

 

 

 

￿￿￿

FD24

Inverter overload factor (OL1 data)

0.01%

 

 

 

 

￿￿￿

FD25

Regenerative braking resistance overload factor (OLr

1%

 

 

 

 

data)

 

 

 

 

 

 

 

 

 

 

 

￿￿￿

FD28

Regenerative braking resistor load factor (% ED)

1%

 

 

 

 

￿￿￿

FD29

Input power

0.01kW

 

 

 

 

￿￿￿

FD30

Output power

0.01kW

 

 

 

 

￿￿￿

FE39

Optional AI2 input

0.01%

 

 

 

 

6

 

￿￿￿

FE35

RR/S4 input

0.01%

 

 

 

 

 

 

 

￿￿￿

FE36

VI/II input

0.01%

 

 

 

 

￿￿￿

FE37

RX input

0.01%

 

 

 

 

￿￿￿

FE38

Optional AI1 input

0.01%

 

 

 

 

￿￿￿

FE40

FM output

0.01%

 

 

 

 

￿￿￿

FE41

AM output

0.01%

 

 

 

 

￿￿￿

FE76

Integral input power

0.01kWhr

 

 

 

 

￿￿￿

FE77

Integral output power

0.01kWhr

 

 

 

 

￿￿￿

FE60

My function monitor 1

1c

 

 

 

 

￿￿￿

FE61

My function monitor 2

1c

 

 

 

 

￿￿￿

FE62

My function monitor 3

1c

 

 

 

 

￿￿￿

FE63

My function monitor 4

1c

 

 

 

Acquisition of trace data

Trace data is acquired through a communication device. The VF-AS1 supports the protocols listed below.

RS485 (Standard protocol)

F-79