6.26 Stall prevention function
6.26.1 Power running stall continuous trip detec tion time
H
HH
H
: Power running stall continuous trip detection time
• Function
A function for preventing lifting gear from failing accidentally. If the stall prevention function is activated in
succession, the inverter judges that the motor has stalled and trips.
[Parameter setting]
Title Function Adjustment range Default setting
H Power running stall continuous trip detection time ~ sec. 
Time [s]"
Output frequency [Hz]
Time [s] "
Output current [%]
H
less than
H
H
QV” trip
"
6.26.2 Regenerative braking stall prevention mode selection"
""
"
H
HH
H : Regenerative braking stall prevention mode selection
• Function
A function for preventing lifting gear from stopping in the wrong position. Only the function of preventing a
stall by maintaining the current constant during regenerative braking (deceleration stop) is deactivated.
[Parameter setting]
Title Function Adjustment range Default setting
H Regenerative braking stall prevention
mode selection
Q:Stall during regenerative braking
:Not stall during regenerative braking
6.26.3 Stall prevention control switching"
""
"
H
HH
H : Stall prevention control switching
• Function
The operation of the stall prevention control can be switched.
Set
H=
when the overvoltage trip etc. are
displayed when acceleration and the deceleration are switched.
This parameter is effective at only V/f control mode(RV =0,1,5).
[Parameter setting]
Title Function Adjustment range Default setting
H Stall prevention control switching Q: Stall prevention control
: Stall prevention control 2