K-3

!

2. Basic parameter [3/4]

 

 

 

 

 

 

 

 

Sensorless vector/vector with sensor (￿:Effective, -:Ineffective)

 

Communi

 

 

 

 

 

 

 

Minimum

 

 

Vector control

 

 

 

Title

cation

Function

 

 

Adjustment range

 

setting unit

Default

Write during

Speed

Torque

PM

V/f

Reference

 

 

 

(Panel/Communi

setting

running

control

 

No.

 

 

 

 

 

 

 

control

control

 

 

 

 

 

 

 

 

 

 

cation)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿

0600

Motor electronic thermal

10~100%

 

 

 

 

1/1

100

Enabled

￿/￿

￿/￿

￿

￿

5. 14

protection level 1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Setting

Motor type

 

Overload

 

OL stall

 

 

 

 

 

 

 

 

 

 

 

 

protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

￿ (protect)

 

× (No stall)

 

 

 

 

 

 

 

 

 

 

Electronic thermal

1

Standard

 

￿ (protect)

 

￿ (stall)

 

 

 

 

 

 

 

 

￿￿￿￿

 

2

Motor

 

× (No Protection)

 

× (No stall)

1/1

0

Enabled

￿/￿

 

￿

￿

5. 14

0017

protection characteristic

 

 

5. 14

3

 

 

× (No Protection)

 

￿ (stall)

 

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

￿ (protect)

 

× (No stall)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

VF Motor

 

￿ (protect)

 

￿ (stall)

 

 

 

 

 

 

 

 

 

 

 

6

 

× (No Protection)

 

× (No stall)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

× (No Protection)

 

￿ (stall)

 

 

 

 

 

 

 

 

￿￿￿￿￿

0701

Current/voltage unit

0:%, 1:A (ampere)/V (volt)

 

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

5. 15

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0005

FM terminal meter

0~76 *1

 

 

 

 

 

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

5. 16

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿

0006

FM terminal meter

-

 

 

 

 

 

1/1

*4

Enabled

￿/￿

￿/￿

￿

￿

5. 16

adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0670

AM terminal meter

0~76 *1

 

 

 

 

 

1/1

2

Enabled

￿/￿

￿/￿

￿

￿

5. 16

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿

0671

AM terminal meter

-

 

 

 

 

 

1/1

*4

Enabled

￿/￿

￿/￿

￿

￿

5. 16

adjustment

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿

0300

PWM carrier frequency

1.0~16.0kHz (2.5~8.0kHz) *2

 

0.1/0.1

*3

Enabled

￿/￿

￿/￿

￿

￿

5. 17

 

 

 

0:Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Auto-restart control

1:At auto-restart after momentary stop

 

 

 

 

 

 

 

 

 

￿￿￿￿

0301

2:When turning ST on or off

 

1/1

0

Disabled

￿/￿

￿/￿

￿

￿

5. 18.1

selection

 

 

 

3:1+2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4:At start-up

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0:Disabled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1:Power ride-through

 

 

 

 

 

 

 

 

 

 

 

Regenerative power

2:Deceleration stop during power failure

 

 

 

 

￿/￿

 

￿

￿

 

￿￿￿￿

0302

3:Synchronized deceleration/acceleration (synchronized

1/1

0

Disabled

-/-

5. 18. 2

ride-through control

 

 

acceleration/deceleration signal)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4:Synchronized deceleration/acceleration (synchronized

 

 

 

 

 

 

 

 

 

 

 

acceleration/deceleration signal+power failure)

 

 

 

 

 

 

 

 

*1: ￿ For the adjustment range, see the table on page K-40.

*2: For 200V-55/75kW models and 400V-90kW to 400V-500kW models, the carrier frequency is between 2.5 and 8.0kHz inclusive.

*3: Default values vary depending on the capacity. ￿ See the table of K-48.

*4: Default setting value is adjusted for connection of frequency meters "QS60T". (Between FM and CCA: Approx. 3.6V) (Between AM and CCA: Approx. 3.6V)

11

!

!

E6581301

Page 257
Image 257
Toshiba VF-AS1 instruction manual E6581301