E6581301

12.Specifications

12.1Models and their standard specifications

1)Standard specifications (small/medium capacity types)

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

200V class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicable motor (kW)

0.4

 

0.75

 

1.5

 

2.2

 

3.7/4.0

5.5

 

 

7.5

 

11

 

 

15

 

 

18.5

 

22

 

30

37

 

45

 

 

Applicable motor (HP)

0.5

 

1

 

2

 

3

 

5

 

 

7.5

 

 

10

 

15

 

 

20

 

 

25

 

30

 

40

50

 

60

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VFAS1-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form

2004PL

2007PL

2015PL

2022PL

2037PL

2055PL

2075PL

2110PM

2150PM

2185PM

2220PM

2300PM

2370PM

2450PM

 

 

Output capacity (kVA)

1.1

 

1.8

 

3.0

 

4.2

 

6.7

 

10

 

 

13

 

21

 

 

25

 

 

29

 

34

 

46

55

 

67

 

 

Rating

[Note 1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output current

3.0

 

4.8

 

8.0

 

11

 

17.5

 

27.5

 

33

 

54

 

 

66

 

 

75

 

88

 

120

144

 

176

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(A)

[Note 2]

(3.0)

 

(4.5)

 

(8.0)

 

(10.5)

 

(16.6)

 

(25.0)

(33)

 

(49)

 

(64)

 

(66)

(75)

 

(88)

(120)

 

(140)

 

 

 

Output voltage

 

 

Three-phase 200V~240V (The maximum output voltage is equal to the input supply voltage.)

 

 

 

 

Overload

 

 

 

 

 

 

 

 

 

 

 

150%-1 minute, 165%-2 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical braking

Dynamic

 

 

 

 

 

 

 

 

 

 

Built-in dynamic braking drive circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

braking circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic braking

 

 

 

 

 

 

 

 

 

An external braking resistor (optional)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

resistor

 

 

 

 

 

 

 

 

 

 

 

! ￿ Rating: Refer to 5.19.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

Voltage-frequency

 

 

 

 

! ! ! ! ! ! ! ! ! Three-phase 200~240V-50/60Hz

[Note 3]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Allowable

 

 

 

 

 

 

 

Voltage + 10% - 15%

 

[Note 4]

 

 

Frequency ±5%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fluctuation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protective method

 

 

 

 

 

 

IP20 Enclosed type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP00 Open type

[Note 5]

 

 

 

(IEC60529)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling method

 

 

 

 

 

 

 

 

 

 

 

 

 

Forced air-cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling fan noise (dBA)

43

 

43

 

43

 

55

 

55

 

 

56

 

 

58

 

60

 

 

60

 

 

60

 

60

 

64

64

 

64

 

 

Color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAL7016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMC filter

 

 

 

 

 

 

Built-in

 

 

 

 

 

 

 

Basic filter (Not complies with the European EMC Directive)

 

DC reactor

 

 

 

External DC reactor (option)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Built-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Item

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specification

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Voltage class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

400V class

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Applicable motor (kW)

0.75

 

1.5

2.2

3.7/4.0

5.5

 

7.5

 

11

 

15

 

18.5

 

22

 

30

 

37

 

 

45

 

55

 

75

 

 

Applicable motor (HP)

1

 

2

3

5

7.5

 

10

 

15

 

20

 

25

 

 

30

 

40

 

50

 

 

60

 

75

 

100

 

 

 

Type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

VFAS1-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Form

 

4007PL

4015PL

4022PL

4037PL

4055PL

4075PL

4110PL

4150PL

4185PL

4220PL

4300PL

4370PL

4450PL

4550PL

4750PL

 

 

Output capacity (kVA)

1.8

 

3.1

4.4

8.0

11

 

13

 

21

 

25

 

31

 

 

37

 

50

 

60

 

 

72

 

88

 

122

 

 

Rating

[Note 1]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Output current

2.3

 

4.1

5.8

10.5

14.3

 

17.6

 

27.7

 

33

 

41

 

 

48

 

66

 

79

 

 

94

 

116

 

160

 

 

 

(A)

[Note 2]

(2.3)

 

(4.0)

(4.6)

(8.6)

(13)

 

(17)

 

(25)

 

(32)

 

(37)

 

(38)

 

(53)

 

(60)

 

(75)

 

(93)

 

(120)

 

 

 

Output voltage

 

 

Three-phase 380V~480V (The maximum output voltage is equal to the input supply voltage.)

 

 

 

 

Overload

 

 

 

 

 

 

 

 

 

 

 

150%-1 minute, 165%-2 sec.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

current rating

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical braking

Dynamic

 

 

 

 

 

 

 

 

 

 

Built-in dynamic braking drive circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

braking circuit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dynamic braking

 

 

 

 

 

 

 

 

 

An external braking resistor (optional)

 

 

 

 

 

 

 

 

 

 

 

 

resistor

 

 

 

 

 

 

 

 

 

 

 

! ￿ Rating: Refer to 5.19.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power supply

Voltage-frequenc

 

 

! ! !

! ! !

! ! ! !

! ! ! !

!

Three-phase 380~480V-50/60Hz

[Note 3]

 

 

 

 

 

 

 

 

 

 

Allowable

 

 

 

 

 

 

 

 

 

 

 

 

 

y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

fluctuation

 

 

 

 

 

 

 

Voltage + 10% - 15%

 

[Note 4]

 

 

Frequency ±5%

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Protective method

 

 

 

 

 

 

IP20 Enclosed type

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IP00 Open type [Note 5]

 

 

(IEC60529)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling method

 

 

 

 

 

 

 

 

 

 

 

 

 

Forced air-cooled

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Cooling fan noise (dBA)

43

 

43

43

55

56

 

56

 

58

 

60

 

60

 

 

60

 

64

 

64

 

 

64

 

64

 

64

 

 

Color

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RAL7016

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EMC filter

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Built-in

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC reactor

 

 

 

 

External DC reactor (option)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Built-in

 

 

 

 

 

 

 

 

Note 1: Capacity is calculated at 220V for the 200V models and at 440V for the 400V models.

Note 2: Rated output current when the PWM carrier frequency (parameter ￿￿) is 4kHz or less.

The values between parentheses refer to rated output currents when set to 12kHz.

￿Refer to 1.4.4 ”Current reduction curve” for details.

Note 3: If you are using a 200V-15kW or 400V-2.2kW inverter and the ambient temperature is 40°C or mor e, decrease the PWM carrier frequency to 8kHz. Setting ￿￿￿￿ to ￿ enables you to protect the overload caused by ambient temperature described in page A-23.

An external power supply backup available (optional) (Type: CPS002Z)

Note 4: ±10% when the inverter is used continuously (load of 100%).

Note 5: HN models, 200V-18.5!45kW and 400V-22!75kW are IP20 enclosed type.

L-1

Page 303
Image 303
Toshiba VF-AS1 Models and their standard specifications, Standard specifications small/medium capacity types