[28] Operation panel parameters [1/3]

 

 

 

Sensorless vector/vector with sensor (￿:Effective, -:Ineffective)

 

 

Communi

 

 

Minimum

 

 

Vector control

 

 

 

 

Title

cation

Function

Adjustment range

setting unit

Default

Write during

Speed

Torque

PM

V/f Constant

Reference

 

(Panel/Communi

setting

running

control

 

 

No.

 

 

cation)

 

 

control

control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0700

Parameter write protect

0:Permit

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 1

 

selection

1:Prohibit

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0701

Current/voltage unit selection

0:%, 1:A (ampere)/V (volt)

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

5. 15

 

￿￿￿￿￿

0702

Frequency free unit display

0.00:OFF, 0.01~200.0

0.01/0.01

0.00

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 2

 

magnification

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0703

Frequency free unit conversion

0:All frequencies display free unit conversion

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 2

 

selection

1:PID frequencies free unit conversion

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0705

Free unit display gradient

0:Negative inclination (downward slope)

1/1

!

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 2

 

characteristic

1:Positive inclination (upward slope)

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0706

Free unit display bias

0.00~￿￿ Hz

0.01/0.01

0.00

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 2

 

￿￿￿￿￿

0707

Changing step selection 1

0.00:Disabled, 0.01~￿￿ Hz

0.01/0.01

0.00

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 3

 

￿￿￿￿￿

0708

Changing step selection 2

0:Disabled, 1~255

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 3

 

￿￿￿￿￿

0709

Standard monitor hold function

0:Real time, 1:Peak hold, 2:Minimum hold

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

￿￿￿￿￿

0710

Standard monitor display

0~80 *1

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0711

Status monitor 1 display

Ditto

1/1

1

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0712

Status monitor 2 display

Ditto

1/1

2

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

K

￿￿￿￿￿

0713

Status monitor 3 display

Ditto

1/1

3

Enabled

￿/￿

￿/￿

￿

￿

8. 3

selection

-27

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0714

Status monitor 4 display

Ditto

1/1

4

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0715

Status monitor 5 display

Ditto

1/1

8

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0716

Status monitor 6 display

Ditto

1/1

16

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0717

Status monitor 7 display

Ditto

1/1

15

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0718

Status monitor 8 display

Ditto

1/1

14

Enabled

￿/￿

￿/￿

￿

￿

8. 3

 

selection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0$When standby terminal (ST) is OFF, clear panel

 

 

 

 

 

 

 

 

 

 

 

 

operation command

 

 

 

 

 

 

 

 

 

 

 

Operation command clear

1$When standby terminal (ST) is OFF, remain

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0719

operation command

1/1

1

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 5

 

selection

 

 

 

2$When standby terminal (ST) is OFF or

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

undervoltage alarm occurs, clear operation

 

 

 

 

 

 

 

 

 

 

 

 

command

 

 

 

 

 

 

 

 

 

￿￿￿￿￿

0721

Operation panel stop pattern

0:Deceleration stop

1/1

0

Enabled

￿/￿

￿/￿

￿

￿

6. 36. 6

 

selection

1:Coast stop

 

 

 

 

 

 

 

 

 

 

 

This parameter moves to a fundamental parameter. *1: ￿ For the adjustment range, see the table on page K-40.