K-46

 

 

 

11

 

 

 

 

 

 

!

 

 

 

 

 

 

 

 

 

[Output terminal function setting (2/3)]

 

Sensorless vector/vector with sensor (￿: valid, -: invalid)

Positive

Negative

Function

Speed control

Torque control

PM control

V/f

Reference

logic

logic

 

 

 

 

 

 

 

 

76

77

Inverter healthy output

￿/￿

￿/￿

￿

￿

 

78

79

RS485 communication error

￿/￿

￿/￿

￿

￿

 

80

81

Error code output 1 (6-bit output)

￿/￿

￿/￿

￿

￿

 

82

83

Error code output 2 (6-bit output)

￿/￿

￿/￿

￿

￿

 

84

85

Error code output 3 (6-bit output)

￿/￿

￿/￿

￿

￿

 

86

87

Error code output 4 (6-bit output)

￿/￿

￿/￿

￿

￿

 

88

89

Error code output 5 (6-bit output)

￿/￿

￿/￿

￿

￿

 

90

91

Error code output 6 (6-bit output)

￿/￿

￿/￿

￿

￿

 

92

93

Designated data output 1 (7-bit output)

￿/￿

￿/￿

￿

￿

 

94

95

Designated data output 2 (7-bit output)

￿/￿

￿/￿

￿

￿

 

96

97

Designated data output 3 (7-bit output)

￿/￿

￿/￿

￿

￿

 

98

99

Designated data output 4 (7-bit output)

￿/￿

￿/￿

￿

￿

 

100

101

Designated data output 5 (7-bit output)

￿/￿

￿/￿

￿

￿

 

102

103

Designated data output 6 (7-bit output)

￿/￿

￿/￿

￿

￿

 

104

105

Designated data output 7 (7-bit output)

￿/￿

￿/￿

￿

￿

 

106

107

Light load signal

￿/￿

-/-

￿

￿

 

108

109

Heavy load signal

￿/￿

-/-

￿

￿

 

110

111

Positive torque limit

￿/￿

￿/￿

￿

￿

 

112

113

Negative torque limit

￿/￿

￿/￿

￿

￿

 

114

115

Output for external rush suppression relay

￿/￿

￿/￿

￿

￿

7.2.2

118

119

Completion of stop positioning (for simple positioning)

-/-

-/-

-

-

 

120

121

L-STOP

￿/￿

￿/￿

￿

￿

 

122

123

Power failure synchronized operation

￿/￿

￿/￿

￿

￿

 

124

125

Traverse motion

￿/￿

￿/￿

￿

￿

 

126

127

Traverse deceleration in progress

￿/￿

￿/￿

￿

￿

 

128

129

Part replacement alarm

￿/￿

￿/￿

￿

￿

 

130

131

Overtorque pre-alarm

￿/￿

￿/￿

￿

￿

 

132

133

Operation frequency command 1/2 selection

￿/￿

￿/￿

￿

￿

 

134

135

Failure FL (except emergency stop)

￿/￿

￿/￿

￿

￿

 

164

165

Motor oscillation contro1

￿/￿

-/-

￿

￿

 

#VFA7 Compatibility$

 

 

 

 

 

 

 

 

222

223

My function output 1

￿/￿

￿/￿

￿

￿

 

224

225

My function output 2

￿/￿

￿/￿

￿

￿

 

226

227

My function output 3

￿/￿

￿/￿

￿

￿

 

228

229

My function output 4

￿/￿

￿/￿

￿

￿

 

230

231

My function output 5

￿/￿

￿/￿

￿

￿

 

232

233

My function output 6

￿/￿

￿/￿

￿

￿

 

234

235

My function output 7

￿/￿

￿/￿

￿

￿

 

236

237

My function output 8

￿/￿

￿/￿

￿

￿

 

238

239

My function output 9

￿/￿

￿/￿

￿

￿

 

E6581301!

Page 300
Image 300
Toshiba VF-AS1 120 121, 122 123, 124 125, 126 127, 128 129, 130 131, 132 133, 134 135, 224 225, 226 227, 228 229, 230 231