E6581301
F-8
6
6.3.3 Using the servo lock function!
!!
!
H
HH
H : Input terminal function selection 3 (ST)
H
HH
H : Starting frequency setting
[Parameter setting]
Title Function Adjustment range Example of setting
H Input terminal function selection 3 (ST) ~ 
H Starting frequency setting ~ Hz 
Note 1: This function is enabled only when parameter RV is set to (PG feedback vector control).
Note 2: To activate servo lock, parameter H (starting frequency setting) needs to be s et to [Hz].
Note 3: These parameters are not intended for position control, and if a load larger than the holding power of the
motor is applied, the motor rotates. Keep this in mind.
If parameter H (for selecting a function for the ST terminal) is set to , a servo lock signal is added to the ST
signal. In that case, turning on the signal to the ST terminal activ ates the servo lock function. Note that eve n when the
servo lock function is activated, or the operations can be perfor med normally by inputting an F or R signal .
Output frequency [Hz]
Servo lock signal
+ST signal
F signal
0
Time [s]
Coasting
R signal
Servo lock status
!
Even if the motor is started with servo lock activated, a starting torque of 150% or more can be produced.
In such a case, however, the thermal protection level is lowered just as is the case with low-
speed operation.
Therefore, the following parameters
QNO (Thermal protection characteristic selection)
VJT (Motor electronic-thermal protection level 1), H, H, H
H (OL reduction starting frequency)
H (Motor 150%-overload time limit)
need to be adjusted according to the motor.
6.3.4 Modifying output terminal functions!
!!
!
H
HH
H : Output terminal function selection 1 (OUT1)
H
HH
H : Output terminal function selection 2 (OUT2)
H
HH
H : Output terminal function selection 3 (FL)
H
HH
H ~ H
HH
H : Output terminal function selection 4~9
H
HH
H ~ H
HH
H : Output terminal function selection 10, 11
For details, refer to Section 7.2.2.
• Function
As with the operation of a server motor, these parameters allow you to operate the motor at 0Hz by simply
issuing an operation signal. These parameters are used to hold the motor at a standstill.