E6581301

[Ex. Countermeasure - inverter wiring]

￿

Control wiring (Shielded cabless)

Relay contact output FLA, FLB, FLC

Control wiring (Shielded cabless)

Logic input/output +SU, F, R, S1"S3, RES,

 

 

 

ST, NO, P24/PLC, OUT1,

 

 

 

OUT2, CC

 

 

 

 

 

 

 

EMC FILTER

 

 

 

 

 

 

Power supply wiring (Shielded cabless)

 

R/L1, S/L2, T/L3

 

 

 

 

 

9

Braking resistor wiring (Shielded cabless)

 

 

 

PA/+, PB ￿

Strip and earth the shielded cable, following the example shown in Fig.

Peel off the outer sheath of the cable and fix the shielded part with a metal saddle.

EMC plate (Refer to Table 2.)

PG feedback signal line (Shielded cabless)!

4-wire RS485 communication line (Shielded cabless)!

Control wiring (Shielded cabless)! Analog input VI/II, RR/S4, PP, CCA Analog output FM, AM, CCA

Motor wiring (Shielded cabless)

U/T1, V/T2, W/T3

Fig. 2

[Operation with external signals]

When using signals from an external control device to operate the inverter, take the measures shown in Figure 3. Ex.) When using the potentiometer and forward run/reverse run terminals

Ferrite core 1

Shielded cable or [Note 1]

Fig. 3

I-6