Opticon OPR 2001 Optical Specifications, Laser Scanning Specifications, Scanning Curvature

Models: OPR 2001

1 42
Download 42 pages 63.75 Kb
Page 11
Image 11

Opticon

OPR 2001

Specifications Manual

6.Optical Specifications

6.1. Laser Scanning Specifications

Parameter

Specification

 

 

Light-emitting element

Red laser diode

 

 

Emission wavelength

650 ±10 (25° C)

 

 

Light output

1.0 or less

 

 

Scanning method

Bi-directional scanning

 

 

Scanning speed

100 ±20

 

 

Scan angle

Scan angle: 54 ±5

 

 

 

Read angle: 44 (Min)

 

 

Unit

-

nm

mW

-

scans/s

°

°

6.2.Laser Scanning Standard

6.2.1.Laser Scanning Tilt

Scanning tilt is the vertical difference between the ends of a laser scan line.

Up to 0.92° in a vertical direction from the scan origin (mirror motor mirror).

Up to 2.46 mm when measured at 150 mm from the scan origin. Measurement is done at the center of the laser scan line.

6.2.2.Scanning Curvature

Scanning curvature is the maximum difference between the laser scan line and the line between the ends of the laser scan line.

Up to 1.17° in a vertical direction from the scan origin (mirror motor mirror).

Up to 3.06 mm when measured at 150 mm from the scan origin. Measurement is done from the center of the laser scan line.

Figure 2: Laser scanning tilt and curvature

11

Page 11
Image 11
Opticon OPR 2001 Optical Specifications, Laser Scanning Specifications, Laser Scanning Standard Laser Scanning Tilt